Entry number 252165
keyword=re-establishing beam, return to production
12:18 Beam returns, 2 uA
Did BeO check.
Checked BPMA, BPMB --> ok within tolerance
Checked Spot++ --> ok, see fig 1.
Put in He target.
Do the raster / rate scan (2x2, 3x4, 4x5, 5x6.6)
Run #4222 during the raster scan.
Raster ... T1-rate ... T3-rate
3x4 .... 13.5 kHz .... 480 Hz
2x2 .... 14 kHz ...... 460 Hz ... event 9000
4x5 .... 13 kHz ...... 480 Hz ... 23K
5x6.6 .. 13.5 kHz .... 480 Hz ... 31K
Rates pretty stable -- see fig 2.
Returning to 12 uA production
We do the following for Helium target:
1. Manual flip ("Flip Now" button)
2. Set auto flip on.
Start run 4223, first production.