5:05 The reference cell pressure is 95 psig of H2.
5:06 Start venting reference cell of its residual H2 gas. Left gauge reads about 726 Torr after vent.
5:07 Start evacuating (pumping out) reference cell.
5:10 The pressures at vacuum are -034 Torr and -021 psig.
5:10 Start filling the reference cell with 3He gas.
5:17 Filled reference cell to 125 psig. Do manual flip of 3He pol. target and turn off autoflip.
5:20 Moved 3He reference cell into position.