NEXT
Make New Entry,
Make Followup Entry
User name Jin Huang
Log entry time 03:29:28 on February 14, 2009
Entry number 261058
This entry is a followup to: 261030
keyword=Dead time after thr change / new scalar replay
Several prescale combo has been tried to opimize data taking
after T6 thrshould
change. The final setting was to take ~3KHz T2 and 200Hz
T6 and bring the DT to 6% (consitant between Datamon
and BBNormAna).
Besides, since data rate doubled, the total event for each run
was set to
5M, bringing file spliting from 3splits to 5
splits.
A new scalar replay tool is setup for experts:
replay_scalar_BB(<run#>). it's
suggested to replay1M events
(=5min data taking time). It would take 5-10min to finish the
analysis (totally
depends on the raw data file read speed) and generate a 10MB-
slim root file.
Time Line
- 12:24
Changing T6 Thr to -80mV
- 12:25 Strarting run 1404; Prescale to 0 T1; 1KHz T2; 100Hz
T6; Off line 180K events
DT = 5.7% (could be much smaller)
- 12:31 Starrting run 1405; Prescale to 0 T1; 2KHz T2; 170Hz
T6; Off line 1M events
DT = 3.9%
- 1:50 Starting run 1409; Prescale to 0 T1; 3KHz T2; 200Hz
T6; Off line 1M events
DT = 6.3%
A copy of this log entry has been emailed to: brads, moffit, kalyan