    User name R. Subedi

    Log entry time 19:13:02 on May 05, 2009

    Entry number 271101

    Followups:

    keyword=Access activity for T8 problem

    Took escorted access to troubleshoot the high rate and high deadtime caused by RHRS T8. Looking into T8 in the delay module I saw that there was another ECL cable just above T8 whose other end was not connected anywhere. As soon as I unplugged that ECL cable, rate and deadtime (observed 1%) went normal. After coming to the counting house and watching the deadtime for a longer time we saw that it fluctuated between 0 to 10 % for a cosmic run. Not sure why is that (T8 prescaled to 100). Another thing unclear to me was how did it work until now since the unturminated ECl cable was sittig there for a long time without a problem. May be the "solution" it appeared to work now is very temporary and the problem is related to somewhere else.

    A copy of this log entry has been emailed to: peter,rom,moffit,zhaobo