• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels / D. Wang

    Log entry time 22:20:33 on May 5,2009

    Entry number 271158

    keyword=Compton test runs

    Start 21:30 
    Runs with the new Compton DAQ configs and normal beam conditions.
    
    Run 16814 .... Prod_FA config .... no beam at start of run
    Run 16815 .... Prod_FA
    
    Switch to Prod_FT
    
    Run 16816 .... Prod_FT config
    
    Finish 22:15 ... Return to normal Production, start run 16817.
    
    I'd like the experts to check these runs.
    For convenience I copied them to /work/halla/parity/disk1/bob
    
    Observations :
    
    1. The Compton logbook shows normal results for run 16814, so 
    the FADC data probably does no harm.  Run 16815 may have been
    too short.  16816 looks ok too.
    
    2. Running the Compton analysis by hand, we see lots of complaints
    about "unknown ROC6" -- trivial to fix.  ROC6 is new FADC crate.
    
    3. CMU analysis code needs a simple change in mainanal.cc:
    pROCdata=datafile.getROCdata(6,MyDebug);