Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name Bo/Vince
Log entry time 19:43:39 on May 11, 2009
Entry number 272630
keyword=Update on checking ROC8 busy signal
Vince and I check R-arm buffered DAQ with ROC8 busy signal after the
daily meeting. We still have the same problem: R-arm DAQ is busy all the
time when pluging ROC8 busy. We see a 40 us ROC8 busy signal, which is
different to that 12 us wide signal in this morning when R-arm buffered
DAQ was working.
We unplug the run-gate from L-arm. In fact R-arm DAQ is running
independently now. We even unplug the inhibit singal of TS, but still
have the same problem. We also test with a new TwinAx cable from Ed, but
it is not an issue of TwinAx cable in fact. It is strange that the ROC8
busy signal is 12 us long in this morning, but 40 us long in the afternoon.
A copy of this log entry has been emailed to: vasulk, rom, moffit, doug, jastrzem