    User name V. Sulkosky

    Log entry time 11:59:37 on May12,2009

    Entry number 272680

    keyword=Moved R-HRS VDC TOP HV

    I obtained a 1471N board from Doug and Seamus, which has been
    installed in the R-HRS HV crate in slot # 3. I have connected the
    R-HRs TOP VDC HV to channel 0 in this slot. The current trip limit
    was set to 10 uA for all channels in this module. I also set the HV
    ramp up rate to be 50 V/s.

    If the HV trips, one will need to disable and re-enable this channel
    to reset the top HV. The bottom HV is still reset via the crate
    resets utility from the Hall A Tools page.

    Shift workers should be informed that the R_TOP display will no longer
    indicate the HV for the top VDC chamber for the R-HRS.