Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name A. Tobias
Log entry time 08:32:25 on May13,2009
Entry number 272956
keyword=Owl Shift Summary
OWL SHIFT SUMMARY 13 MAY 2009
00:00 Test runs on D2 to checkout BB-arm continues (Miha). Taking D2 production runs on RHRS-ND. Later in the shift we find Happex ROC26 was not responding for about 1.75 hours between 3-5AM (see below).
02:15 Approximately at this time, keyboard on hacsbc2 does not respond anymore. All windows are alive & updating, mouse works.
04:00 Approximately at this time, MCC calls and asks us to check with our cameras to see if the roll-up door at the ramp down in the Hall is open or not. We verify the door is open.
05:15 In the Happex DAQ ROC26 was not responding. We reset the DAQ but realize we did not stop the LHRS & RHRS runs. Stop and restart everything. NOTE: The Happex ROC26 was not responding for 1.75 hours between 3-5AM. This is during RHRS D2 production runs 21064 and 21065.
05:25 Start new HAPPEX run 31364.
05:32 Start RHRS D2 production run 21066 and LHRS-unbuffered deadtime check run 2164.
06:33 Start LHRS-unbuffered w/ T1 & T3 triggers only test run 2165.
07:43 run 2166 LHRS-unbuffered like 2165 except BB = 390A.
07:59 run 21067 RHRS D2 production run.