Entry number 272997
This entry is a followup to: 272811
keyword=Re: Updated End-of-Run Deadtime Calculation L-HRS
Doug told me that I should make every T5 to be a T6 in the deadtime
calculation for the end-of-run summary. Hence, I did the exact opposite,
I made every T6 a T5.
The T6 rate is about a factor of 2 smaller than T5. Hence, I believe it
should be the way I implemented it.