    User name V. Sulkosky

    Log entry time 11:26:26 on May 13, 2009

    Entry number 272997

    This entry is a followup to: 272811

    keyword=Re: Updated End-of-Run Deadtime Calculation L-HRS

    Doug told me that I should make every T5 to be a T6 in the deadtime
    calculation for the end-of-run summary. Hence, I did the exact opposite,
    I made every T6 a T5.

    The T6 rate is about a factor of 2 smaller than T5. Hence, I believe it
    should be the way I implemented it.