Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name Jin Huang
Log entry time 11:58:29 on May 26, 2009
Entry number 276586
This entry is a followup to: 275296
Followups:
keyword=EPR Calibration for Transverse- Field of Cell Moss; Correct Coils are turned on
As a attempt to increase target polarization, small correction coil is
turned on to 0.5A (~15mG/cm) to reduce possible massing effect. An EPR is
performed afterward as NMR calibration.
== Test Condition ==
Cell: Moss
Oven Temperature: 230C
Field Direction: Transverse -
Laser Power: 3x25 COMET
Cell Density: 7.962 amg
Correction Coil: Small = 0.50A; Large = 0.00A
== K ==
Pumping Direction: Anti-Parallel
Data directory: C:\AyeD\EPR\Data\EPR_AFP_20090526_1132
Calibration Constant: 1.85 %/mV
Polarization: 55.37%
Field: 24.87 G
EPR Frequency Shift: 101.27 kHz
A copy of this log entry has been emailed to: yqiang, rsubedi, jpchen
Figure 1

Figure 2

Figure 3