    User name ellie

    Log entry time 17:26:59 on May 26, 2009

    Entry number 276613

    keyword=Changed HAND HV

    Changing the following HAND HV to improve TDC counts:

    V-22L (Crate bbps1:2001, L1.9) to -1050 V (was -1025 V)
    N1-6L (Crate bbps1:2001, L3.1) to -1740 V (was -1750 V)
    N1-1R (Crate bbps1:2001, L13.0) to -1512 V (was -1502 V)
    N3-11L (Crate bbps1:2001, L10.0) to -1750 V (was -1765 V)
    N3-12L (Crate bbps1:2001, L8.1) to -1705 V (was -1720 V)
    N3-10R (Crate bbps1:2002, L2.3) to -2350 V (was -2360 V)
    N3-11R (Crate bbps1:2002, L2.4) to -1815 V (was -1830 V)
    N3-12R (Crate bbps1:2002, L2.5) to -1750 V (was -1760 V)