• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name miham

    Log entry time 07:30:02 on May 27, 2009

    Entry number 276797

    keyword=Beam current change

    After we changed the beam current from 10uA to 12uA,
    triggers rates have changed as follows:
    
     Trigger | 10uA rate  | 12uA rate | rel. change
    --------------------------------------------------
       T3    |   1.017 E4 |  1.228 E4 |  1.2
       T5    |   7.114 E2 |  9.78 E2  |  1.4
    
    From this we see that rate in T5 has not changed linearly
    as T3 did. This relative change is also observed in the attached
    trigger plots. When we look at the T5-trigger TDC plot we can see
    that the the number of random coincidences has increased a bit,
    while the "physics peak" stayed the same. 
    
    In the rest of the plots we did not observe any significant change. 
    
    
    
    
    
    
    
    





    Left arm Triggers



    Left arm trigger TDCs



    Right arm triggers



    ND - TDC



    ND - TDC



    ND - TDC