Log entry time 12:15:15 on June 09, 2009
Entry number 280107
Followups:
keyword=D2 bottle is connected to reference cell, but it's almost empty
I connected the last D2 bottle to the reference cell. I first vacuumed
the connection tube by doing the following steps:
1. Keep the D2 bottle valve closed
2. Open the regulator to maximum
3. Fill the reference cell with H2
4. Vacuum the reference cell again
5. Repeat step 3 and 4 a couple of more times
6. Close the regulator
Then I opened the D2 bottle and the regulator. Unfortunately, I got only
about 140 psi out of it, which means we probably can only fill the
reference cell up to 30 psig, which is definitely not efficient for the
D2 reference cell run in my opinion. I talked to Doug and he will look
into it.