• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 14:36:21 on July 29, 2009

    Entry number 282777

    keyword=Start_Parity_Run_10936__CODA_Config=TestCrate
    Right septum lower coil T                :  MSEPRLOWCOILT --- Invalid channel name
    Beginning-of-Parity-run EPICS data for Run Number 10936 at Wed Jul 29 14:36:06 EDT 2009
    CODA Configuration: TestCrate
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 17840
    Wien angle                               : 0.195965
    Wien BDL                                 : 0
    Wien field                               : 0
    Laser attenuation Hall A                 : 116
    Laser power  Hall A                      : 100
    temperature loop 3-3                     :  haITC502_3_Sensor_3_R --- Invalid channel name
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 6.17
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.64
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.715
    Gun2: PC (PITA) NEG                      : 7.7396
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00977
    Pockels Cell Voltage NEG                 : 1.8315
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : No Delay
    G0 Helicity Pattern Set                  : Quartet
    IPM1H04B.XPOS                            :  IPM1H04B.XPOS --- Invalid channel name
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : No Delay
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    Parity DAQ Feedback Control(1=on)        : 1
    LUMI HV - Ch  10                         :  MF1b1461_14ch10property.F --- Invalid channel name
    Right septum yoke T                      :  MSEPRYOKET --- Invalid channel name
    pressure loop D2                         :  haH2_P_Fill_Target_R --- Invalid channel name
    IPM1H04B.YPOS                            :  IPM1H04B.YPOS --- Invalid channel name
    LUMI HV - Ch  0                          :  MF1b1461_14ch0property.F --- Invalid channel name
    LUMI HV - Ch  11                         :  MF1b1461_14ch11property.F --- Invalid channel name
    Right septum bore shield  T              :  MSEPLBORESHT --- Invalid channel name
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.000402969
    Right Arm Q1 gauss meter                 : -2.76e-05
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : -7.76453e-05
    Right Arm Q2 momentum                    : -8.59125e-08
    Right Arm Q2 gauss meter                 : -0.000276
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00359011
    Right Arm D1 momentum                    : 0.00505928
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : -0.000127034
    Right Arm Q3 momentum                    : -3.19255e-07
    Right Arm Q3 gauss meter                 : -0.0002805
    Right Arm Q3 power supply polarity       : enabled
    pressure loop H2                         :  haD2_P_Fill_Target_R --- Invalid channel name
    Survey X offset bpmA                     :  IPM1H04A.XSOF --- Invalid channel name
    LUMI HV - Ch  1                          :  MF1b1461_14ch1property.F --- Invalid channel name
    HAPPEX Detector1 HV - Left Slot10 Ch8    :  MF7b1461_10ch8property.F --- Invalid channel name
    Sweeper Power Supply CMD                 :  MSW1C00ONCMD --- Invalid channel name
    pressure loop He                         :  haHe3_P_Fill_Target_R --- Invalid channel name