    User name apar

    Log entry time 14:09:47 on August 8, 2009

    Entry number 283410

    keyword=Start_Parity_Run_11117__CODA_Config=Injector
    Beginning-of-Parity-run EPICS data for Run Number 11117 at Sat Aug  8 14:09:11 EDT 2009
    CODA Configuration: Injector
    Injector
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    Wien angle                               : 0.195965
    Wien BDL                                 : 0
    Wien field                               : 0
    Laser attenuation Hall A                 : 130
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 5
    Beginning-of-Parity-run EPICS data for Run Number 11117 at Sat Aug  8 14:09:12 EDT 2009
    CODA Configuration: Injector
    Injector
    IA Cell Setpoint  Hall C                 : 5
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    PZT X Setpoint  Hall A                   : 5.25
    Compton Run Number                       : 0
    PZT Y Setpoint  Hall A                   : 5
    Wien angle                               : 0.195965
    PZT X Setpoint  Common                   : 5.64
    Wien BDL                                 : 0
    PZT Y Setpoint  Common                   : 5
    Wien field                               : 0
    Gun2: PC (PITA) POS                      : 7.332
    Laser attenuation Hall A                 : 130
    Gun2: PC (PITA) NEG                      : 7.397
    Laser power  Hall A                      : 100
    Gun3: PC (PITA) POS                      : 5.0246
    Beam Half-wave plate Set(off=out)        : OUT
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00488
    Beam Half-wave plate Read(off=out)       : OUT
    Pockels Cell Voltage NEG                 : 1.83883
    Rotating waveplate                       : 0
    G0 Helicity Settle Set                   : 500 usec
    IA Cell Setpoint  Hall A                 : 5
    G0 Helicity Delay Set                    : 8 cycles
    IA Cell Setpoint  Hall C                 : 5
    G0 Helicity Pattern Set                  : Quartet
    PZT X Setpoint  Hall A                   : 5.25
    G0 Helicity Random/Toggle Set            : Random
    PZT Y Setpoint  Hall A                   : 5
    G0 Helicity Settle Read                  : 500 usec
    PZT X Setpoint  Common                   : 5.64
    G0 Helicity Delay Read                   : 8 cycles
    PZT Y Setpoint  Common                   : 5
    G0 Helicity Pattern Read                 : Quartet
    Gun2: PC (PITA) POS                      : 7.332
    G0 Helicity Random/Toggle Read           : Random
    Parity DAQ Feedback Control(1=on)        : 0
    Gun2: PC (PITA) NEG                      : 7.397
    Left Arm arm angle                       : -0.179
    Gun3: PC (PITA) POS                      : 5.0246
    Right Arm arm angle                      : 0.197
    Gun3: PC (PITA) NEG                      : 5
    Left Arm Q1 power supply current         : 0
    Pockels Cell Voltage POS                 : 2.00733
    Left Arm Q1 momentum                     : 0.000438096
    Pockels Cell Voltage NEG                 : 1.84127
    Left Arm Q1 gauss meter                  : 0.0003282
    G0 Helicity Settle Set                   : 500 usec
    Left Arm Q1 power supply polarity        : 0
    G0 Helicity Delay Set                    : 8 cycles
    Left Arm Q2 power supply current         : -0.000539107
    G0 Helicity Pattern Set                  : Quartet
    Left Arm Q2 momentum                     : -1.25199e-06
    G0 Helicity Random/Toggle Set            : Random
    Left Arm Q2 gauss meter                  : 0.0002325
    G0 Helicity Settle Read                  : 500 usec
    Left Arm Q2 power supply polarity        : enabled
    G0 Helicity Delay Read                   : 8 cycles
    Left Arm D1 power supply current         : -0.0031348
    G0 Helicity Pattern Read                 : Quartet
    Left Arm D1 momentum                     : 0.0028717
    G0 Helicity Random/Toggle Read           : Random
    Left Arm D1 NMR                          : 0.51993
    Parity DAQ Feedback Control(1=on)        : 0
    Left Arm Q3 power supply current         : -0.00046267
    Left Arm arm angle                       : -0.179
    Left Arm Q3 momentum                     : -1.16214e-06
    Right Arm arm angle                      : 0.197
    Left Arm Q3 gauss meter                  : 0.00062892
    Left Arm Q1 power supply current         : 0
    Left Arm Q3 power supply polarity        : enabled
    Left Arm Q1 momentum                     : 0.000438096
    Right Arm Q1 power supply current        : 0
    Left Arm Q1 gauss meter                  : 0.0003282
    Right Arm Q1 momentum                    : 6.89289e-05
    Left Arm Q1 power supply polarity        : 0
    Right Arm Q1 gauss meter                 : -1.65e-05
    Left Arm Q2 power supply current         : -0.000419305
    Right Arm Q1 power supply polarity       : 0
    Left Arm Q2 momentum                     : -1.25199e-06
    Right Arm Q2 power supply current        : -2.21844e-05
    Left Arm Q2 gauss meter                  : 0.0002325
    Right Arm Q2 momentum                    : -1.11686e-07
    Left Arm Q2 power supply polarity        : enabled
    Right Arm Q2 gauss meter                 : -0.000264
    Left Arm D1 power supply current         : -0.0031348
    Right Arm Q2 power supply polarity       : enabled
    Left Arm D1 momentum                     : 0.0028717
    Right Arm D1 power supply current        : -0.00355127
    Left Arm D1 NMR                          : 0.51993
    Right Arm D1 momentum                    : 0.00425831
    Left Arm Q3 power supply current         : -0.00046267
    Right Arm D1 NMR                         : 0
    Left Arm Q3 momentum                     : -1.16214e-06
    Right Arm Q3 power supply current        : -0.000205497
    Left Arm Q3 gauss meter                  : 0.00062892
    Right Arm Q3 momentum                    : -6.5729e-07
    Left Arm Q3 power supply polarity        : enabled
    Right Arm Q3 gauss meter                 : -0.0002787
    Right Arm Q1 power supply current        : 0
    Right Arm Q3 power supply polarity       : enabled
    Right Arm Q1 momentum                    : 6.89289e-05
    Left Arm Top VDC Current                 : 1.31836
    Right Arm Q1 gauss meter                 : -1.65e-05
    Left Arm Bottom VDC Current              : 1.41602
    Right Arm Q1 power supply polarity       : 0
    Right Arm Top VDC Current                : -1.51367
    Right Arm Q2 power supply current        : -2.21844e-05
    Right Arm Bottom VDC Current             : -1.31836
    Right Arm Q2 momentum                    : -5.15475e-08
    Left Arm Top VDC voltage                 : 0.0170898
    Right Arm Q2 gauss meter                 : -0.000264
    Right Arm Q2 power supply polarity       : enabled
    Left Arm Bottom VDC voltage              : 0.0185547
    Right Arm D1 power supply current        : -0.00355127
    Right Arm Top VDC voltage                : -0.0126953
    Right Arm D1 momentum                    : 0.0042474
    Right Arm Bottom VDC voltage             : -0.0102539
    Right Arm D1 NMR                         : 0
    Average current of the two cavities      : 0.0257992
    Right Arm Q3 power supply current        : -0.000205497
    Current on Unser monitor                 : -6.42639
    Right Arm Q3 momentum                    : -5.16442e-07
    Current on Upstream bcm                  : 0.0368175
    Right Arm Q3 gauss meter                 : -0.0002787
    Current on Downstream bcm                : 0.014781
    Right Arm Q3 power supply polarity       : enabled
    Left Arm Top VDC Current                 : 1.36719
    Left Arm Bottom VDC Current              : 1.36719
    Right Arm Top VDC Current                : -1.51367
    7
    Tiefenbach Hall A energy                 : 6063.87
    
    Tiefenbach Hall C energy                 : 6070.48
    Left Arm Top VDC voltage                 : 0.0170898
    Left Arm Bottom VDC voltage              : 0.0185547
    Right Arm Top VDC voltage                : -0.0126953
    Right Arm Bottom VDC voltage             : -0.0102539
    Delta(E)/E width (MV_AI_DXWID)           : 4.12867
    Average current of the two cavities      : 0.0257992
    MBSY1c Hall A Beam energy                : 6077.87
    Current on Unser monitor                 : -6.05795
    MBSY3c Hall C Beam energy                : 6090.49
    Current on Upstream bcm                  : 0.0368175
    MBSY1c magnet current (amp)              : 0
    Current on Downstream bcm                : 0.014781
    MBSY1c Bdl                               : 1.51674e+06
    Upstream Cavity Coefficient              : 42.6
    IPM1C12.XPOS                             : 0
    Downstream Cavity Coefficient            : 43.8
    IPM1C12.YPOS                             : 0
    Current on IBC0L02 (source)              : 0.00556057
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    Tiefenbach Hall A energy                 : 6063.87
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Tiefenbach Hall C energy                 : 6070.48
    Survey Y offset bpmA                     : -0.9
    Delta(E)/E width (MV_AI_DXWID)           : 4.12867
    Survey X offset bpmB                     : 0.77
    MBSY1c Hall A Beam energy                : 6077.87
    Survey Y offset bpmB                     : -1
    MBSY3c Hall C Beam energy                : 6090.49
    Arc1 dp/p                                : 0
    MBSY1c magnet current (amp)              : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.393896
    MBSY1c Bdl                               : 1.51674e+06
    HacL_HPE1313A:0_Ch58                     : -0.236816
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    HacL_HPE1313A:0_Ch55                     : 22.6074
    IPM1H04A.XPOS                            : 0
    HacL_HPE1313A:0_Ch54                     : -0.230469
    IPM1H04A.YPOS                            : 0
    Left Arm Angle Floor Angle               : 0
    IPM1H04B.XPOS                            : 0
    Left Arm Angle Vernier                   : 0
    IPM1H04B.YPOS                            : 0
    Left Arm Scattering Angle                : -0.179
    Survey X offset bpmA                     : -0.63
    Right Arm Collimator                     : 0.362891
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    HacR_HPE1313A:0_Ch58                     : -0.625977
    Survey Y offset bpmB                     : -1
    HacR_HPE1313A:0_Ch55                     : 22.1191
    Arc1 dp/p                                : 0
    HacR_HPE1313A:0_Ch54                     : -0.969238
    Arc2 dp/p                                : 0
    Right Arm Angle Floor Angle              : 0
    Left Arm Collimator                      : 0.393896
    Right Arm Angle Vernier                  : 0
    HacL_HPE1313A:0_Ch58                     : -0.236816
    Right Arm Scattering Angle               : 0.197
    HacL_HPE1313A:0_Ch55                     : 22.6074
    Arc OTR  x-position                      : -10.5973
    HacL_HPE1313A:0_Ch54                     : -0.230469
    Arc OTR  y-position                      : 5
    Left Arm Angle Floor Angle               : 0
    Arc OTR  x-width                         : 0
    Left Arm Angle Vernier                   : 0
    Arc OTR  y-width                         : -0
    Left Arm Scattering Angle                : -0.179
    Arc OTR  data valid flag                 : No
    Right Arm Collimator                     : 0.362891
    Arc OTR  In/Out                          : OTR is Out
    HacR_HPE1313A:0_Ch58                     : -0.625977
    HacR_HPE1313A:0_Ch55                     : 22.1191
    HacR_HPE1313A:0_Ch54                     : -0.969238
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    Arc OTR  x-position                      : -10.5973
    Arc OTR  y-position                      : 5
    Arc OTR  x-width                         : 0
    Arc OTR  y-width                         : -0
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out