keyword=Start_Parity_Run_20187__CODA_Config=Inj2Crate
Beginning-of-Parity-run EPICS data for Run Number 20187 at Wed Aug 12 23:17:40 EDT 2009
CODA Configuration: Inj2Crate
Inj2Crate
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
Wien angle : 0.195965
Wien BDL : 0
Wien field : 0
Laser attenuation Hall A : 88
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.64
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.893
Gun2: PC (PITA) NEG : 6.899
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00488
Pockels Cell Voltage NEG : 1.84127
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
Left Arm Q1 power supply current : 100.725
Left Arm Q1 momentum : 0.133948
Left Arm Q1 gauss meter : -0.008252
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 96.8224
Left Arm Q2 momentum : 0.222468
Left Arm Q2 gauss meter : 0.05073
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5547
Left Arm D1 momentum : 0.298889
Left Arm D1 NMR : 0.197764
Left Arm Q3 power supply current : 101.135
Left Arm Q3 momentum : 0.255309
Left Arm Q3 gauss meter : -0.050264
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.480659
Right Arm Q1 momentum : 0.000795334
Right Arm Q1 gauss meter : -3.5e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0137654
Right Arm Q2 momentum : -3.35488e-05
Right Arm Q2 gauss meter : -0.0002398
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0265075
Right Arm D1 momentum : 0.00756548
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 99.7276
Right Arm Q3 momentum : 0.248461
Right Arm Q3 gauss meter : 0.04409
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 1.31836
Left Arm Bottom VDC Current : 1.36719
Right Arm Top VDC Current : -1.51367
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : -0.0102539
Average current of the two cavities : 0.0262426
Current on Unser monitor : -6.41584
Current on Upstream bcm : 0.0387645
Current on Downstream bcm : 0.0137207
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.0051775
Tiefenbach Hall A energy : 6063.87
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 21.1371
MBSY3c Hall C Beam energy : 21.1371
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 5274.8
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.393945
HacL_HPE1313A:0_Ch58 : -0.23584
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.234375
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.362891
HacR_HPE1313A:0_Ch58 : -0.624512
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.968262
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out