    User name apar

    Log entry time 23:17:47 on August 12, 2009

    Entry number 283962

    keyword=Start_Parity_Run_20187__CODA_Config=Inj2Crate
    Beginning-of-Parity-run EPICS data for Run Number 20187 at Wed Aug 12 23:17:40 EDT 2009
    CODA Configuration: Inj2Crate
    Inj2Crate
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    Wien angle                               : 0.195965
    Wien BDL                                 : 0
    Wien field                               : 0
    Laser attenuation Hall A                 : 88
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 9000
    IA Cell Setpoint  Hall A                 : 4.8
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.64
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.893
    Gun2: PC (PITA) NEG                      : 6.899
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00488
    Pockels Cell Voltage NEG                 : 1.84127
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    Parity DAQ Feedback Control(1=on)        : 0
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    Left Arm Q1 power supply current         : 100.725
    Left Arm Q1 momentum                     : 0.133948
    Left Arm Q1 gauss meter                  : -0.008252
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 96.8224
    Left Arm Q2 momentum                     : 0.222468
    Left Arm Q2 gauss meter                  : 0.05073
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 98.5547
    Left Arm D1 momentum                     : 0.298889
    Left Arm D1 NMR                          : 0.197764
    Left Arm Q3 power supply current         : 101.135
    Left Arm Q3 momentum                     : 0.255309
    Left Arm Q3 gauss meter                  : -0.050264
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.480659
    Right Arm Q1 momentum                    : 0.000795334
    Right Arm Q1 gauss meter                 : -3.5e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0137654
    Right Arm Q2 momentum                    : -3.35488e-05
    Right Arm Q2 gauss meter                 : -0.0002398
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 0.0265075
    Right Arm D1 momentum                    : 0.00756548
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : 99.7276
    Right Arm Q3 momentum                    : 0.248461
    Right Arm Q3 gauss meter                 : 0.04409
    Right Arm Q3 power supply polarity       : disabled
    Left Arm Top VDC Current                 : 1.31836
    Left Arm Bottom VDC Current              : 1.36719
    Right Arm Top VDC Current                : -1.51367
    Right Arm Bottom VDC Current             : -1.46484
    Left Arm Top VDC voltage                 : 0.0175781
    Left Arm Bottom VDC voltage              : 0.0180664
    Right Arm Top VDC voltage                : -0.012207
    Right Arm Bottom VDC voltage             : -0.0102539
    Average current of the two cavities      : 0.0262426
    Current on Unser monitor                 : -6.41584
    Current on Upstream bcm                  : 0.0387645
    Current on Downstream bcm                : 0.0137207
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.0051775
    Tiefenbach Hall A energy                 : 6063.87
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 21.1371
    MBSY3c Hall C Beam energy                : 21.1371
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 5274.8
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.393945
    HacL_HPE1313A:0_Ch58                     : -0.23584
    HacL_HPE1313A:0_Ch55                     : 23.1934
    HacL_HPE1313A:0_Ch54                     : -0.234375
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.362891
    HacR_HPE1313A:0_Ch58                     : -0.624512
    HacR_HPE1313A:0_Ch55                     : 22.2168
    HacR_HPE1313A:0_Ch54                     : -0.968262
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    Arc OTR  x-position                      : -10.5973
    Arc OTR  y-position                      : 5
    Arc OTR  x-width                         : 0
    Arc OTR  y-width                         : -0
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out