NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 11:10:52 on August 14, 2009
Entry number 284377
keyword=Start_Parity_Run_20215__CODA_Config=_Run_type=parityscan,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=RHWP scan PC off,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=out,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 20215 at Fri Aug 14 11:10:46 EDT 2009
CODA Configuration:
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
Wien angle : 17.496
Wien BDL : 398.03
Wien field : 11.563
Laser attenuation Hall A : 89
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.64
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.563
Gun2: PC (PITA) NEG : 7.82
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.84127
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Compton Cavity Power : 427.638
???? : 387.338
??? : -1.66392
??? : -1.27449
??? : 112.215
??? : 494.152
??? : 2.94081
??? : -581.07
??? : 1620[c]
??? : -385[c]
??? : 35.8
??? : RIGHT
??? : 0.65
??? : 0.563389
??? : 0.0714154
??? : 135
??? : 4.94598
??? : +50.8010
??? : 97.787
??? : 0.373972
??? : 32.8942
??? : 0
Parity DAQ Feedback Control(1=on) : 0
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
Left Arm Q1 power supply current : 100.725
Left Arm Q1 momentum : 0.133963
Left Arm Q1 gauss meter : -0.008249
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 96.8339
Left Arm Q2 momentum : 0.222512
Left Arm Q2 gauss meter : 0.05074
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.3534
Left Arm D1 momentum : 0.00335523
Left Arm D1 NMR : 0.381029
Left Arm Q3 power supply current : 101.135
Left Arm Q3 momentum : 0.255374
Left Arm Q3 gauss meter : -0.050268
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.480659
Right Arm Q1 momentum : 0.000715801
Right Arm Q1 gauss meter : -6.5e-06
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0138283
Right Arm Q2 momentum : -3.21313e-05
Right Arm Q2 gauss meter : -0.000239
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.03959
Right Arm D1 momentum : 0.00848663
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 99.7279
Right Arm Q3 momentum : 0.248461
Right Arm Q3 gauss meter : 0.04409
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.51367
Right Arm Bottom VDC Current : -1.12305
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : 3.99951
Average current of the two cavities : 0.0261601
Current on Unser monitor : -7.5635
Current on Upstream bcm : 0.0387286
Current on Downstream bcm : 0.0135917
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.005025
Tiefenbach Hall A energy : 6063.87
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 6077.86
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.51674e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.393945
HacL_HPE1313A:0_Ch58 : -0.230469
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.0942383
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.362891
HacR_HPE1313A:0_Ch58 : -0.625977
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.949219
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out