NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 22:24:39 on August 14, 2009
Entry number 284493
keyword=Start_Parity_Run_20236__CODA_Config=_Run_type=parityscan,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=RHWP scan, nominal pita 0,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 20236 at Fri Aug 14 22:24:33 EDT 2009
CODA Configuration:
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
Wien angle : 17.496
Wien BDL : 398.03
Wien field : 11.563
Laser attenuation Hall A : 90
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 3500
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.64
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.654
Gun2: PC (PITA) NEG : 7.138
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Compton Cavity Power : 0.140713
???? : 395.314
??? : -1.60654
??? : -1.14387
??? : 162.955
??? : 488.954
??? : -26.6809
??? : -595.48
??? : 1120[c]
??? : -850[c]
??? : 35.8
??? : RIGHT
??? : 0.65
??? : 0.803882
??? : 0.151987
??? : 135
??? : -5.20967
??? : +48.1453
??? : 16.8094
??? : 0.00457633
??? : 0.0064257
??? : 0
Parity DAQ Feedback Control(1=on) : 0
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
Left Arm Q1 power supply current : 100.671
Left Arm Q1 momentum : 0.133932
Left Arm Q1 gauss meter : -0.008239
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 96.8232
Left Arm Q2 momentum : 0.22238
Left Arm Q2 gauss meter : 0.05067
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.00259506
Left Arm D1 momentum : 0.0033093
Left Arm D1 NMR : 0.170306
Left Arm Q3 power supply current : 101.134
Left Arm Q3 momentum : 0.255339
Left Arm Q3 gauss meter : -0.050266
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.480659
Right Arm Q1 momentum : 0.0011824
Right Arm Q1 gauss meter : -4.23e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0133439
Right Arm Q2 momentum : -3.10058e-05
Right Arm Q2 gauss meter : -0.0002455
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0404337
Right Arm D1 momentum : 0.010021
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 99.7285
Right Arm Q3 momentum : 0.248461
Right Arm Q3 gauss meter : 0.04409
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.5625
Right Arm Bottom VDC Current : -2.68555
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0195312
Right Arm Top VDC voltage : -0.0126953
Right Arm Bottom VDC voltage : 4
Average current of the two cavities : 0.0261335
Current on Unser monitor : -5.68274
Current on Upstream bcm : 0.0388595
Current on Downstream bcm : 0.0134074
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00505925
Tiefenbach Hall A energy : 6063.87
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 6077.87
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.51674e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.393994
HacL_HPE1313A:0_Ch58 : -0.211914
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0429688
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.362891
HacR_HPE1313A:0_Ch58 : -0.637695
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.975098
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out