    User name apar

    Log entry time 13:05:03 on August 17, 2009

    Entry number 284666

    keyword=Start_Parity_Run_44146__CODA_Config=_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=LED tests, both LED inside the detector,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 44146 at Mon Aug 17 13:04:56 EDT 2009
    CODA Configuration:
    
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    Wien angle                               : 17.496
    Wien BDL                                 : 398.03
    Wien field                               : 11.563
    Laser attenuation Hall A                 : 80
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.8
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.64
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.554
    Gun2: PC (PITA) NEG                      : 6.238
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00733
    Pockels Cell Voltage NEG                 : 1.84371
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : No Delay
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : No Delay
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
     Laser power                                                   : Pwr725mW
     Calculated power in cavity                                    : 950.287
     Photodiode on table                                           : 401.047
     Laser X position on QPD 1                                     : 162.674
     Laser Y position on QPD 1                                     : 485.714
     Laser X position on QPD 2                                     : -28.5532
     Laser Y position on QPD 2                                     : -604.924
     QPD 1 sum                                                     : -1.64561
     QPD 2 sum                                                     : -1.14509
     Position set point for adjustable mirror 1 (either x or y)    : -885[c]
     Position set point for adjustable mirror 2 (either x or y)    : -3880[c]
     Laser crystal minimum temperature (epics constant used for calculating temperature offsets)   : 35.8
     Laser temperature set point                                   : +48.1485
     Polarisation set point of laser in cavity                     : RIGHT
     Signal reflected from cavity input mirror                     : 0.350974
     Gain of locking servo                                       : 135
     Tracking level (V) of locking servo                         : 0.65
     Slow locking signal sent to laser                             : 0.181285
     Fast locking signal sent to laser                             : -7.89416
     Calculated polarisation in cavity                             : 98.0734
     Signal of one polarisation state after Wollaston prism        : 0.725658
     Signal of other polarisation state after Wollaston prism      : 74.6051
     Step size for rotating half wave plate scan                   : 11162
     Slow ramping of laser temperature when not locked (1 = on)    : ON
     Extent of laser temperature slow ramp (degrees C)             : 0.2
     Speed of laser temperature slow ramp up                       : 150
     Speed of laser temperature slow ramp down                     : 150
    Parity DAQ Feedback Control(1=on)        : 0
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    Left Arm Q1 power supply current         : 100.725
    Left Arm Q1 momentum                     : 0.133729
    Left Arm Q1 gauss meter                  : -0.008238
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 96.824
    Left Arm Q2 momentum                     : 0.222248
    Left Arm Q2 gauss meter                  : 0.05068
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 98.544
    Left Arm D1 momentum                     : 0.2985
    Left Arm D1 NMR                          : 0.481885
    Left Arm Q3 power supply current         : 101.135
    Left Arm Q3 momentum                     : 0.255264
    Left Arm Q3 gauss meter                  : -0.050252
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 100.458
    Right Arm Q1 momentum                    : 0.132397
    Right Arm Q1 gauss meter                 : -0.002517
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 99.6586
    Right Arm Q2 momentum                    : 0.228233
    Right Arm Q2 gauss meter                 : 0.05162
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 0.1726
    Right Arm D1 momentum                    : 0.0062546
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : 99.7283
    Right Arm Q3 momentum                    : 0.248461
    Right Arm Q3 gauss meter                 : 0.04409
    Right Arm Q3 power supply polarity       : disabled
    Left Arm Top VDC Current                 : 4.19922
    Left Arm Bottom VDC Current              : 3.71094
    Right Arm Top VDC Current                : -29.7852
    Right Arm Bottom VDC Current             : 0.78125
    Left Arm Top VDC voltage                 : 4.00781
    Left Arm Bottom VDC voltage              : 4.00098
    Right Arm Top VDC voltage                : 3.99854
    Right Arm Bottom VDC voltage             : 4.01025
    Average current of the two cavities      : 0.0260876
    Current on Unser monitor                 : -7.09392
    Current on Upstream bcm                  : 0.0391337
    Current on Downstream bcm                : 0.0130416
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 1.6898
    Tiefenbach Hall A energy                 : 6063.87
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 6077.87
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 1.51674e+06
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.393994
    HacL_HPE1313A:0_Ch58                     : -0.207031
    HacL_HPE1313A:0_Ch55                     : 23.4863
    HacL_HPE1313A:0_Ch54                     : 0.0400391
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.362842
    HacR_HPE1313A:0_Ch58                     : -0.634277
    HacR_HPE1313A:0_Ch55                     : 22.3145
    HacR_HPE1313A:0_Ch54                     : -0.964355
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    Arc OTR  x-position                      : -10.5973
    Arc OTR  y-position                      : 5
    Arc OTR  x-width                         : 0
    Arc OTR  y-width                         : -0
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out