Make Followup Entry
User name apar
Log entry time 13:54:54 on August 17, 2009
Entry number 284675
keyword=Start_Parity_Run_44155__CODA_Config=_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=LED tests, both LED inside the detector,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 44155 at Mon Aug 17 13:54:46 EDT 2009
CODA Configuration:
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
Wien angle : 90.2438
Wien BDL : 2095.7
Wien field : 60.156
Laser attenuation Hall A : 58
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.64
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.554
Gun2: PC (PITA) NEG : 6.238
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.84371
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Laser power : Pwr720mW
Calculated power in cavity : 0.149673
Photodiode on table : 382.353
Laser X position on QPD 1 : 168.996
Laser Y position on QPD 1 : 472.859
Laser X position on QPD 2 : -28.7681
Laser Y position on QPD 2 : -581.716
QPD 1 sum : -1.65049
QPD 2 sum : -1.13532
Position set point for adjustable mirror 1 (either x or y) : -885[c]
Position set point for adjustable mirror 2 (either x or y) : -3880[c]
Laser crystal minimum temperature (epics constant used for calculating temperature offsets) : 35.8
Laser temperature set point : +48.0656
Polarisation set point of laser in cavity : LEFT
Signal reflected from cavity input mirror : 0.822194
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -0.485259
Calculated polarisation in cavity : 18.5981
Signal of one polarisation state after Wollaston prism : 0.00493386
Signal of other polarisation state after Wollaston prism : 0.00610442
Step size for rotating half wave plate scan : 11162
Slow ramping of laser temperature when not locked (1 = on) : ON
Extent of laser temperature slow ramp (degrees C) : 0.2
Speed of laser temperature slow ramp up : 150
Speed of laser temperature slow ramp down : 150
Parity DAQ Feedback Control(1=on) : 0
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
Left Arm Q1 power supply current : 100.725
Left Arm Q1 momentum : 0.133932
Left Arm Q1 gauss meter : -0.008238
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 96.8249
Left Arm Q2 momentum : 0.222468
Left Arm Q2 gauss meter : 0.05068
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5443
Left Arm D1 momentum : 0.298472
Left Arm D1 NMR : 0.500742
Left Arm Q3 power supply current : 101.135
Left Arm Q3 momentum : 0.255319
Left Arm Q3 gauss meter : -0.050262
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 100.458
Right Arm Q1 momentum : 0.133839
Right Arm Q1 gauss meter : -0.0025473
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 99.6591
Right Arm Q2 momentum : 0.228233
Right Arm Q2 gauss meter : 0.0516
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.1717
Right Arm D1 momentum : 0.00620554
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 99.728
Right Arm Q3 momentum : 0.248461
Right Arm Q3 gauss meter : 0.04409
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -1.5625
Left Arm Bottom VDC Current : 0.244141
Right Arm Top VDC Current : -28.2227
Right Arm Bottom VDC Current : 0.683594
Left Arm Top VDC voltage : 4.00391
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 4.00732
Average current of the two cavities : 0.0259994
Current on Unser monitor : -5.91753
Current on Upstream bcm : 0.0389504
Current on Downstream bcm : 0.0130485
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.660216
Tiefenbach Hall A energy : 6063.87
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 6077.87
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.51674e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.393994
HacL_HPE1313A:0_Ch58 : -0.207031
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.0390625
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.362891
HacR_HPE1313A:0_Ch58 : -0.634277
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.963867
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out