User name apar
Log entry time 16:01:02 on August 17, 2009
Entry number 284704
keyword=Start_Parity_Run_44166__CODA_Config=_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=LED tests, both LEDs power unplugged,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 44166 at Mon Aug 17 16:00:55 EDT 2009
CODA Configuration:
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
Wien angle : 17.496
Wien BDL : 398.03
Wien field : 11.563
Laser attenuation Hall A : 73
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.64
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.554
Gun2: PC (PITA) NEG : 6.238
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00488
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Laser power : Pwr725mW
Calculated power in cavity : 0.146166
Photodiode on table : 385.842
Laser X position on QPD 1 : 184.741
Laser Y position on QPD 1 : 451.809
Laser X position on QPD 2 : -33.8584
Laser Y position on QPD 2 : -550.366
QPD 1 sum : -1.5626
QPD 2 sum : -0.764207
Position set point for adjustable mirror 1 (either x or y) : -885[c]
Position set point for adjustable mirror 2 (either x or y) : -3880[c]
Laser crystal minimum temperature (epics constant used for calculating temperature offsets) : 35.8
Laser temperature set point : +48.2221
Polarisation set point of laser in cavity : LEFT
Signal reflected from cavity input mirror : 0.560947
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 3.65684
Calculated polarisation in cavity : 17.9953
Signal of one polarisation state after Wollaston prism : 0.00500536
Signal of other polarisation state after Wollaston prism : 0.00720214
Step size for rotating half wave plate scan : 11162
Slow ramping of laser temperature when not locked (1 = on) : ON
Extent of laser temperature slow ramp (degrees C) : 0.2
Speed of laser temperature slow ramp up : 150
Speed of laser temperature slow ramp down : 150
Parity DAQ Feedback Control(1=on) : 0
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
Left Arm Q1 power supply current : 100.618
Left Arm Q1 momentum : 0.133588
Left Arm Q1 gauss meter : -0.008229
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 96.8245
Left Arm Q2 momentum : 0.222116
Left Arm Q2 gauss meter : 0.05065
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5414
Left Arm D1 momentum : 0.298555
Left Arm D1 NMR : 0.169553
Left Arm Q3 power supply current : 101.135
Left Arm Q3 momentum : 0.255274
Left Arm Q3 gauss meter : -0.050254
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 100.404
Right Arm Q1 momentum : 0.133669
Right Arm Q1 gauss meter : -0.0025398
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 99.66
Right Arm Q2 momentum : 0.228145
Right Arm Q2 gauss meter : 0.0516
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.118858
Right Arm D1 momentum : 0.00617829
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 99.7277
Right Arm Q3 momentum : 0.248461
Right Arm Q3 gauss meter : 0.04409
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -1.02539
Left Arm Bottom VDC Current : 4.05273
Right Arm Top VDC Current : 25.1953
Right Arm Bottom VDC Current : 0.976562
Left Arm Top VDC voltage : 4.00635
Left Arm Bottom VDC voltage : 4.00098
Right Arm Top VDC voltage : 4.00098
Right Arm Bottom VDC voltage : 3.99463
Average current of the two cavities : 0.0255742
Current on Unser monitor : -6.24816
Current on Upstream bcm : 0.0384462
Current on Downstream bcm : 0.0127021
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00517769
Tiefenbach Hall A energy : 6063.87
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 5871.82
MBSY3c Hall C Beam energy : 5884.04
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.46532e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.393994
HacL_HPE1313A:0_Ch58 : -0.207031
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.0410156
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.362891
HacR_HPE1313A:0_Ch58 : -0.633789
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.963867
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out