    User name apar

    Log entry time 04:27:21 on August 21, 2009

    Entry number 285086

    keyword=Start_Parity_Run_11503__CODA_Config=_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=Harp scan is not ready,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 11503 at Fri Aug 21 04:26:28 EDT 2009
    CODA Configuration:
    
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 18228
    -----------------------------------------
    Wien angle                               : 31.7994
    Wien BDL                                 : 727.52
    Wien field                               : 21.121
    Laser attenuation Hall A                 : 66
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.8
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.64
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.554
    Gun2: PC (PITA) NEG                      : 6.238
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00488
    Pockels Cell Voltage NEG                 : 1.84371
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr725mW
    Calculated power in cavity               : 0.157886
    Photodiode on table                      : 400.798
    Laser X position on QPD 1                : 177.526
    Laser Y position on QPD 1                : 477.554
    Laser X position on QPD 2                : -37.6848
    Laser Y position on QPD 2                : -592.261
    QPD 1 sum                                : -1.68711
    QPD 2 sum                                : -1.17927
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -885[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -3900[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +48.1453
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.812427
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -1.38986
    Calculated polarisation in cavity        : 17.4152
    Photodiode 1 after Wollaston prism       : 0.00701473
    Photodiode 2 after Wollaston prism       : 0.00493386
    Step size for RHWP scan                  : 11162
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    LUMI003 HV - Ch  1                          :  MF1b1461_15ch1property.F --- Invalid channel name
    LUMI004 HV - Ch  2                          :  MF1b1461_15ch2property.F --- Invalid channel name
    LUMI005 HV - Ch  4                          :  MF1b1461_15ch4property.F --- Invalid channel name
    LUMI006 HV - Ch  5                          :  MF1b1461_15ch5property.F --- Invalid channel name
    LUMI007 HV - Ch  6                          :  MF1b1461_15ch6property.F --- Invalid channel name
    LUMI009 HV - Ch  7                          :  MF1b1461_15ch7property.F --- Invalid channel name
    LUMI001 HV - Ch  10                         :  MF1b1461_15ch10property.F --- Invalid channel name
    LUMI002 HV - Ch  11                         :  MF1b1461_15ch11property.F --- Invalid channel name
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1201.9
    HAPPEX Det, right arm HV - Right Slot14 Ch9  :  MF1b1461_14ch9property.F --- Invalid channel name
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 752.445
    Left Arm Q1 momentum                     : 1.00015
    Left Arm Q1 gauss meter                  : -0.06334
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 430.59
    Left Arm Q2 momentum                     : 0.999978
    Left Arm Q2 gauss meter                  : 0.2271
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 332.591
    Left Arm D1 momentum                     : 0.999995
    Left Arm D1 NMR                          : 0.370229
    Left Arm Q3 power supply current         : 398.305
    Left Arm Q3 momentum                     : 0.999861
    Left Arm Q3 gauss meter                  : -0.201545
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 752.071
    Right Arm Q1 momentum                    : 1.00018
    Right Arm Q1 gauss meter                 : -0.018796
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 430.443
    Right Arm Q2 momentum                    : 1.00018
    Right Arm Q2 gauss meter                 : 0.2255
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 342.703
    Right Arm D1 momentum                    : 1.00001
    Right Arm D1 NMR                         : 0.371092
    Right Arm Q3 power supply current        : 397.973
    Right Arm Q3 momentum                    : 1.00016
    Right Arm Q3 gauss meter                 : 0.17788
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : -1.2207
    Left Arm Bottom VDC Current              : -1.41602
    Right Arm Top VDC Current                : -26.4648
    Right Arm Bottom VDC Current             : -1.36719
    Left Arm Top VDC voltage                 : 4.00488
    Left Arm Bottom VDC voltage              : 3.99902
    Right Arm Top VDC voltage                : 4
    Right Arm Bottom VDC voltage             : 0.00146484
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0242576
    Current on Unser monitor                 : -6.58414
    Current on Upstream bcm                  : 0.0351183
    Current on Downstream bcm                : 0.013322
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00487625
    Tiefenbach Hall A energy                 : 5859.15
    Tiefenbach Hall C energy                 : 5865.52
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 1198.33
    MBSY3c Hall C Beam energy                : 2436.5
    MBSY1c magnet current (amp)              : 49.6642
    MBSY1c Bdl                               : 299044
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.870801
    HacL_HPE1313A:0_Ch58                     : -0.203613
    HacL_HPE1313A:0_Ch55                     : 24.0234
    HacL_HPE1313A:0_Ch54                     : 0.0366211
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.862305
    HacR_HPE1313A:0_Ch58                     : -0.630371
    HacR_HPE1313A:0_Ch55                     : 22.8027
    HacR_HPE1313A:0_Ch54                     : -0.95459
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -10.5973
    Arc OTR  y-position                      : 5
    Arc OTR  x-width                         : 0
    Arc OTR  y-width                         : -0
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------