Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name Ramesh/Dustin/ALex
Log entry time 21:32:49 on August21,2009
Entry number 285175
keyword=HRS triggers ready
We took controlled access to finish trigger timing issues. In both HRSs the retiming cable is just unplugged (not needed). All signals (Happex PMT, Prex PMTs, S0 PMTs) in both HRSs are well within the gate. Happex signals are centered inside the gate (perfect timing). In addition, all triggers in both HRSs are perfectly aligned to each other.
Gate widths:
LHRS: ADC and TDC gates each 250 ns wide
RHRS: ADC gate is 400 ns wide while TDC gate is 250 ns wide.
Any signal has more than 50 ns clearance from the falling edge of any gate.
Trigger definitions are as follows:
LHRS:
T1: Happex signal
T2: S0 front PMT signal ANDed with S0 back PMT signal
T8: 1024 Hz clock
RHRS:
T1: Happex signal
T2: S0 front PMT signal ANDed with S0 back PMT signal
T3: Prex Stack PMT signal
T8: 1024 Hz clock