    User name apar

    Log entry time 07:26:42 on August 24, 2009

    Entry number 285661

    keyword=Start_Parity_Run_11549__CODA_Config=happex3_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=looking at lumi signals with OS=1 and IT=6600 with BCM ADCs on HI gain,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 11549 at Mon Aug 24 07:25:49 EDT 2009
    CODA Configuration: happex3
    happex3
    
    # Timing board information: # Integrate Time = 16.50 ms, Ramp Delay = 0.00 us oversamp 2
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : 44.706
    Wien BDL                                 : 1025.2
    Wien field                               : 29.744
    Laser attenuation Hall A                 : 84
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.8
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.554
    Gun2: PC (PITA) NEG                      : 6.238
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00733
    Pockels Cell Voltage NEG                 : 1.83639
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr725mW
    Calculated power in cavity               : 0.147232
    Photodiode on table                      : 391.326
    Laser X position on QPD 1                : 176.021
    Laser Y position on QPD 1                : 479.96
    Laser X position on QPD 2                : -36.8362
    Laser Y position on QPD 2                : -590.136
    QPD 1 sum                                : -1.57847
    QPD 2 sum                                : -1.09015
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -885[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -4120[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +48.0413
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.809986
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 6.45486
    Calculated polarisation in cavity        : 17.8094
    Photodiode 1 after Wollaston prism       : 0.00655957
    Photodiode 2 after Wollaston prism       : 0.00457633
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    LUMI003 HV - Ch  1                          :  MF1b1461_15ch1property.F --- Invalid channel name
    LUMI004 HV - Ch  2                          :  MF1b1461_15ch2property.F --- Invalid channel name
    LUMI005 HV - Ch  4                          :  MF1b1461_15ch4property.F --- Invalid channel name
    LUMI006 HV - Ch  5                          :  MF1b1461_15ch5property.F --- Invalid channel name
    LUMI007 HV - Ch  6                          :  MF1b1461_15ch6property.F --- Invalid channel name
    LUMI009 HV - Ch  7                          :  MF1b1461_15ch7property.F --- Invalid channel name
    LUMI001 HV - Ch  10                         :  MF1b1461_15ch10property.F --- Invalid channel name
    LUMI002 HV - Ch  11                         :  MF1b1461_15ch11property.F --- Invalid channel name
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1600.1
    HAPPEX Det, right arm HV - Right Slot14 Ch9  :  MF1b1461_14ch9property.F --- Invalid channel name
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 877.15
    Left Arm Q1 momentum                     : 1.16591
    Left Arm Q1 gauss meter                  : -0.07394
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 502.051
    Left Arm Q2 momentum                     : 1.16593
    Left Arm Q2 gauss meter                  : 0.2647
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 388.163
    Left Arm D1 momentum                     : 1.166
    Left Arm D1 NMR                          : 0.431648
    Left Arm Q3 power supply current         : 464.18
    Left Arm Q3 momentum                     : 1.16593
    Left Arm Q3 gauss meter                  : -0.23423
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 1033.58
    Right Arm Q1 momentum                    : 1.37079
    Right Arm Q1 gauss meter                 : -0.025823
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1008.42
    Right Arm Q2 momentum                    : 2.32375
    Right Arm Q2 gauss meter                 : 0.5186
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 412.69
    Right Arm D1 momentum                    : 1.20202
    Right Arm D1 NMR                         : 0.446056
    Right Arm Q3 power supply current        : 478.266
    Right Arm Q3 momentum                    : 1.20195
    Right Arm Q3 gauss meter                 : 0.2135
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 5.27344
    Left Arm Bottom VDC Current              : 0.927734
    Right Arm Top VDC Current                : -28.2227
    Right Arm Bottom VDC Current             : -3.17383
    Left Arm Top VDC voltage                 : 4.00684
    Left Arm Bottom VDC voltage              : 3.99951
    Right Arm Top VDC voltage                : 3.99854
    Right Arm Bottom VDC voltage             : 4.00293
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 20.1699
    Current on Unser monitor                 : 15.1804
    Current on Upstream bcm                  : 19.6604
    Current on Downstream bcm                : 20.6794
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 20.2917
    Tiefenbach Hall A energy                 : 1197.39
    Tiefenbach Hall C energy                 : 2332.88
    Delta(E)/E width (MV_AI_DXWID)           : 3.90448
    MBSY1c Hall A Beam energy                : 1198.33
    MBSY3c Hall C Beam energy                : 2338.32
    MBSY1c magnet current (amp)              : 49.6642
    MBSY1c Bdl                               : 299044
    IPM1C12.XPOS                             : -0.00753215
    IPM1C12.YPOS                             : 0.208918
    IPM1H04A.XPOS                            : 0.4243
    IPM1H04A.YPOS                            : 0.240421
    IPM1H04B.XPOS                            : -0.0039475
    IPM1H04B.YPOS                            : -0.024013
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.367383
    HacL_HPE1313A:0_Ch58                     : -0.202637
    HacL_HPE1313A:0_Ch55                     : 23.291
    HacL_HPE1313A:0_Ch54                     : 0.0405273
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.615674
    HacR_HPE1313A:0_Ch58                     : -0.626465
    HacR_HPE1313A:0_Ch55                     : 22.168
    HacR_HPE1313A:0_Ch54                     : -0.967285
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -2.12061
    Arc OTR  y-position                      : -1.41727
    Arc OTR  x-width                         : 2.94726
    Arc OTR  y-width                         : 2.21709
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------