    User name apar

    Log entry time 11:35:37 on August 24, 2009

    Entry number 285691

    keyword=Start_Parity_Run_44303__CODA_Config=TestCrate_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=looking at lumi signals... try adcx sampling by 2 with gain 3,0. BCMs are HI, 23_3 is LO,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 44303 at Mon Aug 24 11:34:48 EDT 2009
    CODA Configuration: TestCrate
    TestCrate
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : 90.2438
    Wien BDL                                 : 2089.4
    Wien field                               : 60.156
    Laser attenuation Hall A                 : 130
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.8
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.554
    Gun2: PC (PITA) NEG                      : 6.238
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00733
    Pockels Cell Voltage NEG                 : 1.83639
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr720mW
    Calculated power in cavity               : 0.141729
    Photodiode on table                      : 390.578
    Laser X position on QPD 1                : 177.122
    Laser Y position on QPD 1                : 479.42
    Laser X position on QPD 2                : -33.6257
    Laser Y position on QPD 2                : -592.763
    QPD 1 sum                                : -1.59311
    QPD 2 sum                                : -1.0987
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -885[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 860[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2072
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.845388
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 3.17707
    Calculated polarisation in cavity        : 16.1631
    Photodiode 1 after Wollaston prism       : 0.00650602
    Photodiode 2 after Wollaston prism       : 0.00469551
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    LUMI003 HV - Ch  1                          :  MF1b1461_15ch1property.F --- Invalid channel name
    LUMI004 HV - Ch  2                          :  MF1b1461_15ch2property.F --- Invalid channel name
    LUMI005 HV - Ch  4                          :  MF1b1461_15ch4property.F --- Invalid channel name
    LUMI006 HV - Ch  5                          :  MF1b1461_15ch5property.F --- Invalid channel name
    LUMI007 HV - Ch  6                          :  MF1b1461_15ch6property.F --- Invalid channel name
    LUMI009 HV - Ch  7                          :  MF1b1461_15ch7property.F --- Invalid channel name
    LUMI001 HV - Ch  10                         :  MF1b1461_15ch10property.F --- Invalid channel name
    LUMI002 HV - Ch  11                         :  MF1b1461_15ch11property.F --- Invalid channel name
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1600.1
    HAPPEX Det, right arm HV - Right Slot14 Ch9  :  MF1b1461_14ch9property.F --- Invalid channel name
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.747692
    Left Arm Q1 momentum                     : 0.00217796
    Left Arm Q1 gauss meter                  : 0.0001779
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.00953545
    Left Arm Q2 momentum                     : 0.00446404
    Left Arm Q2 gauss meter                  : 0.0011339
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.34191
    Left Arm D1 momentum                     : 0.00322245
    Left Arm D1 NMR                          : 0.235749
    Left Arm Q3 power supply current         : 1.37687
    Left Arm Q3 momentum                     : 0.00817002
    Left Arm Q3 gauss meter                  : -0.00086683
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.480659
    Right Arm Q1 momentum                    : 0.00153234
    Right Arm Q1 gauss meter                 : -4.89e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0118464
    Right Arm Q2 momentum                    : -2.66587e-05
    Right Arm Q2 gauss meter                 : 0.0006108
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 2.01882
    Right Arm D1 momentum                    : 0.0474941
    Right Arm D1 NMR                         : 0.167588
    Right Arm Q3 power supply current        : 0.10193
    Right Arm Q3 momentum                    : 0.00255289
    Right Arm Q3 gauss meter                 : 0.0001561
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 4.19922
    Left Arm Bottom VDC Current              : 0.683594
    Right Arm Top VDC Current                : -1.66016
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 4.00537
    Left Arm Bottom VDC voltage              : 3.99951
    Right Arm Top VDC voltage                : -0.0112305
    Right Arm Bottom VDC voltage             : -0.00830078
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0241902
    Current on Unser monitor                 : -6.20779
    Current on Upstream bcm                  : 0.0347549
    Current on Downstream bcm                : 0.0136255
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00452727
    Tiefenbach Hall A energy                 : 1197.39
    Tiefenbach Hall C energy                 : 2332.79
    Delta(E)/E width (MV_AI_DXWID)           : 3.90448
    MBSY1c Hall A Beam energy                : 1198.33
    MBSY3c Hall C Beam energy                : 2338.32
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 299044
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.367383
    HacL_HPE1313A:0_Ch58                     : -0.200684
    HacL_HPE1313A:0_Ch55                     : 23.3887
    HacL_HPE1313A:0_Ch54                     : 0.0429688
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.615625
    HacR_HPE1313A:0_Ch58                     : -0.623535
    HacR_HPE1313A:0_Ch55                     : 22.2168
    HacR_HPE1313A:0_Ch54                     : -0.966797
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -2.12061
    Arc OTR  y-position                      : -1.41727
    Arc OTR  x-width                         : 2.94726
    Arc OTR  y-width                         : 2.21709
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------