Log entry time 13:48:03 on August 24, 2009
Entry number 285700
keyword=Start_Parity_Run_44310__CODA_Config=TestCrate_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=looking at lumi signals... try adcx sampling by 2 with gain 3,0. BCMs are HI, 23_3 is LO,leftarm_p=3.1234,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.1126,rightarm_theta=6,target_fanspeed=90Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 44310 at Mon Aug 24 13:47:13 EDT 2009
CODA Configuration: TestCrate
TestCrate
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 18314
-----------------------------------------
Wien angle : 90.2438
Wien BDL : 2089.4
Wien field : 60.156
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.554
Gun2: PC (PITA) NEG : 6.238
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99267
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr725mW
Calculated power in cavity : 987.846
Photodiode on table : 397.807
Laser X position on QPD 1 : 176.048
Laser Y position on QPD 1 : 480.409
Laser X position on QPD 2 : -37.4411
Laser Y position on QPD 2 : -603.869
QPD 1 sum : -1.60898
QPD 2 sum : -1.10114
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : 860[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +48.2634
Polarisation in cavity : RIGHT
Reflection photodiode : 0.333883
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.18861
Fast locking signal sent to laser : 2.27248
Calculated polarisation in cavity : 98.0586
Photodiode 1 after Wollaston prism : 77.3119
Photodiode 2 after Wollaston prism : 0.757836
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
LUMI003 HV - Ch 1 : MF1b1461_15ch1property.F --- Invalid channel name
LUMI004 HV - Ch 2 : MF1b1461_15ch2property.F --- Invalid channel name
LUMI005 HV - Ch 4 : MF1b1461_15ch4property.F --- Invalid channel name
LUMI006 HV - Ch 5 : MF1b1461_15ch5property.F --- Invalid channel name
LUMI007 HV - Ch 6 : MF1b1461_15ch6property.F --- Invalid channel name
LUMI009 HV - Ch 7 : MF1b1461_15ch7property.F --- Invalid channel name
LUMI001 HV - Ch 10 : MF1b1461_15ch10property.F --- Invalid channel name
LUMI002 HV - Ch 11 : MF1b1461_15ch11property.F --- Invalid channel name
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1600.1
HAPPEX Det, right arm HV - Right Slot14 Ch9 : MF1b1461_14ch9property.F --- Invalid channel name
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0.747692
Left Arm Q1 momentum : 0.00192606
Left Arm Q1 gauss meter : 0.0001859
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.00921348
Left Arm Q2 momentum : 0.00426479
Left Arm Q2 gauss meter : 0.0011216
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.35066
Left Arm D1 momentum : 0.00318236
Left Arm D1 NMR : 0.207271
Left Arm Q3 power supply current : 1.37661
Left Arm Q3 momentum : 0.00813009
Left Arm Q3 gauss meter : -0.0008689
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.480659
Right Arm Q1 momentum : 0.00127253
Right Arm Q1 gauss meter : -4.51e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0122864
Right Arm Q2 momentum : -2.74061e-05
Right Arm Q2 gauss meter : 0.0006146
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.01891
Right Arm D1 momentum : 0.0337558
Right Arm D1 NMR : 0.181647
Right Arm Q3 power supply current : 0.102606
Right Arm Q3 momentum : 0.00255066
Right Arm Q3 gauss meter : 0.0001556
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -1.85547
Left Arm Bottom VDC Current : -1.36719
Right Arm Top VDC Current : -1.46484
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 4.00293
Left Arm Bottom VDC voltage : 4
Right Arm Top VDC voltage : -0.0112305
Right Arm Bottom VDC voltage : -0.00830078
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0241304
Current on Unser monitor : -6.24721
Current on Upstream bcm : 0.0346145
Current on Downstream bcm : 0.0136463
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.150136
Tiefenbach Hall A energy : 1197.39
Tiefenbach Hall C energy : 2332.79
Delta(E)/E width (MV_AI_DXWID) : 3.90448
MBSY1c Hall A Beam energy : 1198.33
MBSY3c Hall C Beam energy : 2338.32
MBSY1c magnet current (amp) : 49.6642
MBSY1c Bdl : 299044
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.367383
HacL_HPE1313A:0_Ch58 : -0.202148
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0419922
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.615674
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.966797
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -2.12061
Arc OTR y-position : -1.41727
Arc OTR x-width : 2.94726
Arc OTR y-width : 2.21709
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------