User name apar
Log entry time 16:59:27 on August 25, 2009
Entry number 285930
keyword=End_of_Parity_Run_44366__CODA_Config=TestCrate
End-of-Parity-run EPICS data for Run Number 44366 at Tue Aug 25 16:59:20 EDT 2009
CODA Configuration: TestCrate
# Timing board information: # Integrate Time = 15.00 ms, Ramp Delay = 0.00 us oversamp 2
Compton Run Number : 18348
-----------------------------------------
Wien angle : 44.3048
Wien BDL : 1013.9
Wien field : 29.476
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.8
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.15
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.554
Gun2: PC (PITA) NEG : 6.238
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr725mW
Calculated power in cavity : 946.958
Photodiode on table : 391.077
Laser X position on QPD 1 : 177.671
Laser Y position on QPD 1 : 479.32
Laser X position on QPD 2 : -36.8017
Laser Y position on QPD 2 : -598.617
QPD 1 sum : -1.55771
QPD 2 sum : -1.06208
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : -4040[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +48.1957
Polarisation in cavity : LEFT
Reflection photodiode : 0.327779
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.100714
Fast locking signal sent to laser : -5.27193
Calculated polarisation in cavity : 1.15828
Photodiode 1 after Wollaston prism : 36.988
Photodiode 2 after Wollaston prism : 37.8787
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1600.1
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 839.712
Left Arm Q1 momentum : 1.11615
Left Arm Q1 gauss meter : -0.07069
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 480.497
Left Arm Q2 momentum : 1.11588
Left Arm Q2 gauss meter : 0.2533
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 371.658
Left Arm D1 momentum : 1.11602
Left Arm D1 NMR : 0.413165
Left Arm Q3 power supply current : 444.245
Left Arm Q3 momentum : 1.11586
Left Arm Q3 gauss meter : -0.22421
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 839.071
Right Arm Q1 momentum : 1.11588
Right Arm Q1 gauss meter : -0.020962
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 480.39
Right Arm Q2 momentum : 1.11623
Right Arm Q2 gauss meter : 0.2517
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 380.163
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.803604
Right Arm Q3 power supply current : 444.128
Right Arm Q3 momentum : 1.11616
Right Arm Q3 gauss meter : 0.19843
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -2.29492
Left Arm Bottom VDC Current : 1.70898
Right Arm Top VDC Current : -27.002
Right Arm Bottom VDC Current : -0.439453
Left Arm Top VDC voltage : 4.00049
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : 3.99316
Right Arm Bottom VDC voltage : 3.9917
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0238802
Current on Unser monitor : -5.38446
Current on Upstream bcm : 0.034185
Current on Downstream bcm : 0.0135753
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.545552
Tiefenbach Hall A energy : 1204
Tiefenbach Hall C energy : 2344.17
Delta(E)/E width (MV_AI_DXWID) : 0.294672
MBSY1c Hall A Beam energy : 1204.94
MBSY3c Hall C Beam energy : 2349.74
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 300694
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.367285
HacL_HPE1313A:0_Ch58 : -0.198242
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0351562
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.615625
HacR_HPE1313A:0_Ch58 : -0.624512
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.96582
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -2.12061
Arc OTR y-position : -1.41727
Arc OTR x-width : 2.94726
Arc OTR y-width : 2.21709
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------