    keyword=Boiling Studies - Ramping Current

    Boiling Studies
    
    Current Ramp
    
    11758 - Tune HVs for Lumis @ 70uA.
    11759 - Good run (long)  at 70uA with HVs: 
            545, 675, 855, 1140, 835, 950, 740, 660
    11760 - Good run (short) at 50uA with same HVs
    11761 - Tune HVs for Lumis @ 50uA.
    11762 - Good run (long)  at 50uA with HVs:
            580, 715, 915, 1220, 890, 1020, 795, 700
    11763 - CODA crashed - ROC31 not responding
    11764 - Good run (short) at 30uA with same HVs
    11765 - Bad run. Panguin crashed.
    11766 - Tune HVs for Lumis @ 30uA.
    11767 - Good run (long)  at 30uA with HVs:
            640, 785, 1020, 1360, 980, 1130, 875, 770
    11768 - Good Run (short) at 20uA with same HVs
    11769 - Tune HVs for Lumis @ 20uA
    11770 - Good Run (long)  at 20uA with HVs:
            685, 840, 1095, 1475, 1050, 1225, 940, 830
    
    
    
    
    Summary:
    (All asymmetry noise levels quoted are in ppm)
    
    Run     I  SUM_RMS  C-X_RMS  BCM1-2
    11759  70   1214      160     111
    11760  50    580      177     138
    11762  50    586      180     142
    11764  30    379      231     217
    11767  30    387      223     212
    11768  20    338      260     361
    11770  20    328      269     362