User name apar
Log entry time 07:09:50 on September 3, 2009
Entry number 287634
keyword=End_of_Parity_Run_44563__CODA_Config=TestCrate
End-of-Parity-run EPICS data for Run Number 44563 at Thu Sep 3 07:09:44 EDT 2009
CODA Configuration: TestCrate
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 18770
-----------------------------------------
Wien angle : 14.1961
Wien BDL : 327.62
Wien field : 9.3576
Laser attenuation Hall A : 140
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.1
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.202
Gun2: PC (PITA) NEG : 6.498
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr635mW
Calculated power in cavity : 0.142179
Photodiode on table : 341.725
Laser X position on QPD 1 : 171.751
Laser Y position on QPD 1 : 476.923
Laser X position on QPD 2 : -32.4675
Laser Y position on QPD 2 : -584.785
QPD 1 sum : -1.30867
QPD 2 sum : -0.937557
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : 840[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1669
Polarisation in cavity : RIGHT
Reflection photodiode : 0.708661
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 8.35195
Calculated polarisation in cavity : 17.7013
Photodiode 1 after Wollaston prism : 0.00661312
Photodiode 2 after Wollaston prism : 0.004624
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1574.9
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.24
Left Arm Q1 momentum : 3.14122
Left Arm Q1 gauss meter : -0.19944
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.63
Left Arm Q2 momentum : 3.14127
Left Arm Q2 gauss meter : 0.7107
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.29
Left Arm D1 momentum : 3.1416
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.65
Left Arm Q3 momentum : 3.1414
Left Arm Q3 gauss meter : -0.63077
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.44
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05869
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352
Right Arm Q2 momentum : 3.1415
Right Arm Q2 gauss meter : 0.7067
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1136.2
Right Arm D1 momentum : 3.14162
Right Arm D1 NMR : 1.16582
Right Arm Q3 power supply current : 1249.88
Right Arm Q3 momentum : 3.14112
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 1.36719
Right Arm Top VDC Current : -1.5625
Right Arm Bottom VDC Current : -1.31836
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.0170898
Right Arm Top VDC voltage : -0.0078125
Right Arm Bottom VDC voltage : -0.00830078
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 98.2865
Current on Unser monitor : 90.2156
Current on Upstream bcm : 95.8268
Current on Downstream bcm : 100.746
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 108.273
Tiefenbach Hall A energy : 3483.93
Tiefenbach Hall C energy : 2344.77
Delta(E)/E width (MV_AI_DXWID) : 2.63981
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.74
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870863
IPM1C12.XPOS : -0.00828552
IPM1C12.YPOS : -0.134214
IPM1H04A.XPOS : -0.187886
IPM1H04A.YPOS : 0.949353
IPM1H04B.XPOS : -2.18558
IPM1H04B.YPOS : 2.1985
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.618945
HacL_HPE1313A:0_Ch58 : -0.198242
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : 0.0263672
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator :
HacR_HPE1313A:0_Ch58 : -0.623535
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.960938
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------