User name apar
Log entry time 13:40:33 on September 13, 2009
Entry number 289348
keyword=Start_Parity_Run_12277__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production 100uA ADC 22 -> hi ( unser signal),dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 12277 at Sun Sep 13 13:40:26 EDT 2009
CODA Configuration: happex3
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19293
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 397.35
Wien field : 11.363
Laser attenuation Hall A : 187
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.26
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.584
Gun2: PC (PITA) NEG : 6.116
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.98535
Pockels Cell Voltage NEG : 1.8486
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr757mW
Calculated power in cavity : 947.717
Photodiode on table : 414.008
Laser X position on QPD 1 : 164.28
Laser Y position on QPD 1 : 493.153
Laser X position on QPD 2 : -37.6621
Laser Y position on QPD 2 : -610.032
QPD 1 sum : -1.61875
QPD 2 sum : -1.12312
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : 920[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2791
Polarisation in cavity : RIGHT
Reflection photodiode : 0.414454
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.68
Slow locking signal sent to laser : 0.067753
Fast locking signal sent to laser : 6.71122
Calculated polarisation in cavity : 97.9255
Photodiode 1 after Wollaston prism : 74.1258
Photodiode 2 after Wollaston prism : 0.776928
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1589.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.19
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19946
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.82
Left Arm Q2 momentum : 3.14172
Left Arm Q2 gauss meter : 0.7107
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1102.95
Left Arm D1 momentum : 3.14165
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.62
Left Arm Q3 momentum : 3.14132
Left Arm Q3 gauss meter : -0.63101
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.39
Right Arm Q1 momentum : 3.14174
Right Arm Q1 gauss meter : -0.05866
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.18
Right Arm Q2 momentum : 3.14193
Right Arm Q2 gauss meter : 0.7065
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.98
Right Arm D1 momentum : 3.14162
Right Arm D1 NMR : 1.16582
Right Arm Q3 power supply current : 1250.18
Right Arm Q3 momentum : 3.14186
Right Arm Q3 gauss meter : 0.5594
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.0175781
Right Arm Top VDC voltage : -0.0112305
Right Arm Bottom VDC voltage : 0.00634766
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 48.0845
Current on Unser monitor : 91.724
Current on Upstream bcm : 96.1465
Current on Downstream bcm : 0.0224298
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 78.3733
Tiefenbach Hall A energy : 3482.34
Tiefenbach Hall C energy : 2343.49
Delta(E)/E width (MV_AI_DXWID) : 4.33384
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619287
HacL_HPE1313A:0_Ch58 : -0.200195
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : 0.0249023
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.615332
HacR_HPE1313A:0_Ch58 : -0.625
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.961914
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 73.5
Encoder position : 17740740
temperature loop 3-1 : 18.96
temperature loop 3-2 : 18.94
temperature loop 3-3 : 0.9
pressure fill target H2 : 28.3925
pressure fill bottle H2 : 29.2409
pressure ballast H2 : 29.3538
pressure exhaust H2 : 27.5273
cryogen input temp : 13.6
crogen return flow : 24.4349
JT valve setting : 53.125
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12277 -d '2009-09-13 13:40:21' -t 17740740 -s IN