Make New Entry,
Make Followup Entry
User name apar
Log entry time 13:33:21 on September 14, 2009
Entry number 289513
keyword=End_of_Parity_Run_12306__CODA_Config=happex3
************************************************
Run Number: 12306
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production with 100uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 12306 at Mon Sep 14 13:33:12 EDT 2009
CODA Configuration: happex3
Compton Run Number : 19363
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 397.35
Wien field : 11.363
Laser attenuation Hall A : 199
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.28
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.618
Gun2: PC (PITA) NEG : 6.082
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr757mW
Calculated power in cavity : 0.156337
Photodiode on table : 404.536
Laser X position on QPD 1 : 172.831
Laser Y position on QPD 1 : 486.987
Laser X position on QPD 2 : -37.9924
Laser Y position on QPD 2 : -596.594
QPD 1 sum : -1.61387
QPD 2 sum : -1.11335
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : 920[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2763
Polarisation in cavity : LEFT
Reflection photodiode : 0.871025
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -4.4479
Calculated polarisation in cavity : 15.6072
Photodiode 1 after Wollaston prism : 0.00669344
Photodiode 2 after Wollaston prism : 0.00488619
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1590.2
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.24
Left Arm Q1 momentum : 3.14122
Left Arm Q1 gauss meter : -0.19944
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.81
Left Arm Q2 momentum : 3.14169
Left Arm Q2 gauss meter : 0.7107
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1102.95
Left Arm D1 momentum : 3.14165
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.61
Left Arm Q3 momentum : 3.14131
Left Arm Q3 gauss meter : -0.63101
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.33
Right Arm Q1 momentum : 3.14167
Right Arm Q1 gauss meter : -0.05866
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.19
Right Arm Q2 momentum : 3.14194
Right Arm Q2 gauss meter : 0.7065
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.94
Right Arm D1 momentum : 3.1416
Right Arm D1 NMR : 1.16581
Right Arm Q3 power supply current : 1250.17
Right Arm Q3 momentum : 3.14185
Right Arm Q3 gauss meter : 0.5594
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : 0.00585938
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 98.9716
Current on Unser monitor : 90.6555
Current on Upstream bcm : 96.6549
Current on Downstream bcm : 101.288
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 104.717
Tiefenbach Hall A energy : 3483.13
Tiefenbach Hall C energy : 2344.16
Delta(E)/E width (MV_AI_DXWID) : 3.45443
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.518564
IPM1C12.YPOS : 0.0713305
IPM1H04A.XPOS : -0.112065
IPM1H04A.YPOS : 1.02642
IPM1H04B.XPOS : -0.774733
IPM1H04B.YPOS : 1.98689
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.518564
Survey Y offset bpm12 : 0.0713305
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619336
HacL_HPE1313A:0_Ch58 : -0.201172
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0234375
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.615234
HacR_HPE1313A:0_Ch58 : -0.624512
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.962891
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 71.5
Encoder position : 17740740
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.91
pressure fill target H2 : 29.2103
pressure fill bottle H2 : 29.9428
pressure ballast H2 : 28.6976
pressure exhaust H2 : 29.0715
cryogen input temp : 13.3
crogen return flow : 24.0488
JT valve setting : 52.9785
-----------------------------------------