Entry number 289586
keyword=End_of_Parity_Run_12318__CODA_Config=happex3
************************************************
Run Number: 12318
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production with 100uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 12318 at Tue Sep 15 01:03:54 EDT 2009
CODA Configuration: happex3
Compton Run Number : 19371
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 397.35
Wien field : 11.363
Laser attenuation Hall A : 193
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.136
Gun2: PC (PITA) NEG : 6.574
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.74847
Pockels Cell Voltage NEG : 1.54335
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 935.369
Photodiode on table : 413.509
Laser X position on QPD 1 : 166.745
Laser Y position on QPD 1 : 490.564
Laser X position on QPD 2 : -39.3977
Laser Y position on QPD 2 : -609.604
QPD 1 sum : -1.6273
QPD 2 sum : -1.128
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : 920[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2218
Polarisation in cavity : RIGHT
Reflection photodiode : 0.405909
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.181285
Fast locking signal sent to laser : -1.6865
Calculated polarisation in cavity : 98.0265
Photodiode 1 after Wollaston prism : 73.1941
Photodiode 2 after Wollaston prism : 0.729424
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1589.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.61
Left Arm Q1 momentum : 3.14172
Left Arm Q1 gauss meter : -0.19945
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.81
Left Arm Q2 momentum : 3.14168
Left Arm Q2 gauss meter : 0.7106
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1102.95
Left Arm D1 momentum : 3.14165
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.61
Left Arm Q3 momentum : 3.1413
Left Arm Q3 gauss meter : -0.63098
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.33
Right Arm Q1 momentum : 3.14167
Right Arm Q1 gauss meter : -0.05866
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.18
Right Arm Q2 momentum : 3.14193
Right Arm Q2 gauss meter : 0.7065
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.94
Right Arm D1 momentum : 3.14162
Right Arm D1 NMR : 1.16582
Right Arm Q3 power supply current : 1250.05
Right Arm Q3 momentum : 3.14155
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0175781
Right Arm Top VDC voltage : -0.0126953
Right Arm Bottom VDC voltage : 0.00585938
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 99.2952
Current on Unser monitor : 92.7123
Current on Upstream bcm : 96.9983
Current on Downstream bcm : 101.592
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 100.895
Tiefenbach Hall A energy : 3484.75
Tiefenbach Hall C energy : 2344.16
Delta(E)/E width (MV_AI_DXWID) : 4.38912
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.447283
IPM1C12.YPOS : 0.135342
IPM1H04A.XPOS : 0.00200397
IPM1H04A.YPOS : 1.03079
IPM1H04B.XPOS : -0.78976
IPM1H04B.YPOS : 2.00487
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.435465
Survey Y offset bpm12 : 0.138042
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619336
HacL_HPE1313A:0_Ch58 : -0.202637
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0214844
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.615234
HacR_HPE1313A:0_Ch58 : -0.624512
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.962891
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 71.5
Encoder position : 17740740
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.91
pressure fill target H2 : 27.6814
pressure fill bottle H2 : 28.2948
pressure ballast H2 : 28.1407
pressure exhaust H2 : 27.3228
cryogen input temp : 13.4
crogen return flow : 24.52
JT valve setting : 53.125
-----------------------------------------