Make Followup Entry
User name apar
Log entry time 12:47:18 on September 16, 2009
Entry number 289955
keyword=End_of_Parity_Run_12387__CODA_Config=happex3
************************************************
Run Number: 12387
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=test run,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
test
************************************************
End-of-Parity-run EPICS data for Run Number 12387 at Wed Sep 16 12:47:08 EDT 2009
CODA Configuration: happex3
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19425
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 75
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A :
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.21
Gun2: PC (PITA) NEG : 6.5
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99512
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.137325
Photodiode on table : 416.75
Laser X position on QPD 1 : 162.527
Laser Y position on QPD 1 : 495.805
Laser X position on QPD 2 : -37.0975
Laser Y position on QPD 2 : -606.867
QPD 1 sum : -1.60288
QPD 2 sum : -1.14021
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : 920[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.3024
Polarisation in cavity : RIGHT
Reflection photodiode : 0.871025
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 4.8471
Calculated polarisation in cavity : 66.6703
Photodiode 1 after Wollaston prism : 0.0234806
Photodiode 2 after Wollaston prism : 0.00469551
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1590.2
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.08
Left Arm Q1 momentum : 3.14101
Left Arm Q1 gauss meter : -0.19945
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.79
Left Arm Q2 momentum : 3.14165
Left Arm Q2 gauss meter : 0.7107
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1102.96
Left Arm D1 momentum : 3.14166
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.6
Left Arm Q3 momentum : 3.14127
Left Arm Q3 gauss meter : -0.63102
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.44
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05867
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.15
Right Arm Q2 momentum : 3.14185
Right Arm Q2 gauss meter : 0.7063
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.88
Right Arm D1 momentum : 3.1416
Right Arm D1 NMR : 1.16581
Right Arm Q3 power supply current : 1250.02
Right Arm Q3 momentum : 3.14148
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.0112305
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 1.19479
Current on Unser monitor : -6.42956
Current on Upstream bcm : 1.16945
Current on Downstream bcm : 1.22013
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 19.8938
Tiefenbach Hall A energy : 3483.06
Tiefenbach Hall C energy : 2344.13
Delta(E)/E width (MV_AI_DXWID) : 3.45745
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.455163
IPM1C12.YPOS : -0.00385615
IPM1H04A.XPOS : -0.217751
IPM1H04A.YPOS : -1.16362
IPM1H04B.XPOS : -0.899718
IPM1H04B.YPOS : 1.61386
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.455163
Survey Y offset bpm12 : -0.00385615
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619336
HacL_HPE1313A:0_Ch58 : -0.200684
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : 0.0229492
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.615332
HacR_HPE1313A:0_Ch58 : -0.627441
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.963379
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72.5
Encoder position : 9054712
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.9
pressure fill target H2 : 28.9296
pressure fill bottle H2 : 29.4499
pressure ballast H2 : 29.5171
pressure exhaust H2 : 28.6381
cryogen input temp : 13.3
crogen return flow : 23.9223
JT valve setting : 52.4902
-----------------------------------------