• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 20:45:10 on September 17, 2009

    Entry number 290198

    keyword=Start_Parity_Run_12436__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production run @ 100uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 12436 at Thu Sep 17 20:45:04 EDT 2009
    CODA Configuration: happex3
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 19463
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 143
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.44
    Gun2: PC (PITA) NEG                      : 6.27
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00733
    Pockels Cell Voltage NEG                 : 1.8315
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr752mW
    Calculated power in cavity               : 873.928
    Photodiode on table                      : 404.536
    Laser X position on QPD 1                : 188.901
    Laser Y position on QPD 1                : 473.002
    Laser X position on QPD 2                : -42.9626
    Laser Y position on QPD 2                : -599.348
    QPD 1 sum                                : -1.75182
    QPD 2 sum                                : -1.1341
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -770[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 899[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.3097
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.379051
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.0494414
    Fast locking signal sent to laser        : -2.49588
    Calculated polarisation in cavity        : 98.1112
    Photodiode 1 after Wollaston prism       : 0.652316
    Photodiode 2 after Wollaston prism       : 68.0038
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1590.2
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : 13.9997
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.08
    Left Arm Q1 momentum                     : 3.14101
    Left Arm Q1 gauss meter                  : -0.1994
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.76
    Left Arm Q2 momentum                     : 3.14157
    Left Arm Q2 gauss meter                  : 0.7106
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1102.97
    Left Arm D1 momentum                     : 3.14163
    Left Arm D1 NMR                          : 1.1634
    Left Arm Q3 power supply current         : 1250.56
    Left Arm Q3 momentum                     : 3.14118
    Left Arm Q3 gauss meter                  : -0.63094
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.39
    Right Arm Q1 momentum                    : 3.14174
    Right Arm Q1 gauss meter                 : -0.05865
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.87
    Right Arm Q2 momentum                    : 3.14121
    Right Arm Q2 gauss meter                 : 0.7061
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.85
    Right Arm D1 momentum                    : 3.14165
    Right Arm D1 NMR                         : 1.16583
    Right Arm Q3 power supply current        : 1249.99
    Right Arm Q3 momentum                    : 3.14139
    Right Arm Q3 gauss meter                 : 0.5592
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.46484
    Left Arm Bottom VDC Current              : 1.36719
    Right Arm Top VDC Current                : -1.61133
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 0.0180664
    Left Arm Bottom VDC voltage              : 0.019043
    Right Arm Top VDC voltage                : -0.0117188
    Right Arm Bottom VDC voltage             : -0.00927734
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 97.9682
    Current on Unser monitor                 : 90.6095
    Current on Upstream bcm                  : 95.7648
    Current on Downstream bcm                : 100.172
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 98.3713
    Tiefenbach Hall A energy                 : 3483.03
    Tiefenbach Hall C energy                 : 2344.17
    Delta(E)/E width (MV_AI_DXWID)           : 3.08651
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0.453596
    IPM1C12.YPOS                             : 0.13181
    IPM1H04A.XPOS                            : -0.258158
    IPM1H04A.YPOS                            : 0.794141
    IPM1H04B.XPOS                            : -0.812796
    IPM1H04B.YPOS                            : 2.10456
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.453596
    Survey Y offset bpm12                     : 0.13181
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.619385
    HacL_HPE1313A:0_Ch58                     : -0.202637
    HacL_HPE1313A:0_Ch55                     : 22.8516
    HacL_HPE1313A:0_Ch54                     : 0.0234375
    Left Arm Angle Floor Angle               : 14
    Left Arm Angle Vernier                   : 31
    Left Arm Scattering Angle                : 13.9997
    Right Arm Collimator                     : 0.615283
    HacR_HPE1313A:0_Ch58                     : -0.626465
    HacR_HPE1313A:0_Ch55                     : 22.2168
    HacR_HPE1313A:0_Ch54                     : -0.963379
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 72.5
    Encoder position                         : 17740744
    temperature loop 3-1                      : 19
    temperature loop 3-2                      : 19
    temperature loop 3-3                      : 0.91
    pressure fill target H2                   : 27.628
    pressure fill bottle H2                   : 28.0812
    pressure ballast H2                       : 27.9591
    pressure exhaust H2                       : 27.4113
    cryogen input temp                        : 13.6
    crogen return flow                        : 24.1595
     JT valve setting                         : 53.7109
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12436 -d '2009-09-17 20:44:33' -t 17740744 -s OUT