User name apar
Log entry time 21:03:29 on September 21, 2009
Entry number 290917
keyword=End_of_Parity_Run_12555__CODA_Config=happex3
************************************************
Run Number: 12555
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production at 100 uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 12555 at Mon Sep 21 21:03:19 EDT 2009
CODA Configuration: happex3
Compton Run Number : 19603
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 150
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.505
Gun2: PC (PITA) NEG : 6.205
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.84371
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 964.4
Photodiode on table : 412.512
Laser X position on QPD 1 : 174.735
Laser Y position on QPD 1 : 482.838
Laser X position on QPD 2 : -39.5761
Laser Y position on QPD 2 : -604.829
QPD 1 sum : -1.70787
QPD 2 sum : -1.14997
Position set point for adjustable
mirror 1 (either x or y) : -875[c]
Position set point for adjustable
mirror 2 (either x or y) : -3990[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2543
Polarisation in cavity : RIGHT
Reflection photodiode : 0.371727
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.239883
Fast locking signal sent to laser : 3.3492
Calculated polarisation in cavity : 97.9792
Photodiode 1 after Wollaston prism : 75.4511
Photodiode 2 after Wollaston prism : 0.770135
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1589.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.08
Left Arm Q1 momentum : 3.14101
Left Arm Q1 gauss meter : -0.19938
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.79
Left Arm Q2 momentum : 3.14164
Left Arm Q2 gauss meter : 0.7106
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1102.96
Left Arm D1 momentum : 3.14163
Left Arm D1 NMR : 1.16339
Left Arm Q3 power supply current : 1250.6
Left Arm Q3 momentum : 3.14127
Left Arm Q3 gauss meter : -0.63097
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2361.85
Right Arm Q1 momentum : 3.14103
Right Arm Q1 gauss meter : -0.05863
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.9
Right Arm Q2 momentum : 3.14127
Right Arm Q2 gauss meter : 0.7062
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.85
Right Arm D1 momentum : 3.14157
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1250.02
Right Arm Q3 momentum : 3.14147
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 1.36719
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0170898
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00878906
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 88.0696
Current on Unser monitor : 80.5129
Current on Upstream bcm : 85.8881
Current on Downstream bcm : 90.2511
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 97.7616
Tiefenbach Hall A energy : 3482.94
Tiefenbach Hall C energy : 2344.11
Delta(E)/E width (MV_AI_DXWID) : 3.15597
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.531256
IPM1C12.YPOS : 0.118293
IPM1H04A.XPOS : -0.284696
IPM1H04A.YPOS : 1.29751
IPM1H04B.XPOS : -0.752628
IPM1H04B.YPOS : 2.04595
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.531256
Survey Y offset bpm12 : 0.118293
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619629
HacL_HPE1313A:0_Ch58 : -0.203125
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.0185547
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.0321777
HacR_HPE1313A:0_Ch58 : -0.625488
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.963867
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 71.5
Encoder position : 17740748
temperature loop 3-1 : 18.98
temperature loop 3-2 : 18.99
temperature loop 3-3 : 0.91
pressure fill target H2 : 27.7974
pressure fill bottle H2 : 28.2826
pressure ballast H2 : 26.8605
pressure exhaust H2 : 27.4327
cryogen input temp : 13.7
crogen return flow : 24.3949
JT valve setting : 52.832
-----------------------------------------