Log entry time 09:31:54 on September 22, 2009
Entry number 290990
keyword=Start_Parity_Run_12569__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production at 100 uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 12569 at Tue Sep 22 09:31:17 EDT 2009
CODA Configuration: happex3
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19615
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 75
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.486
Gun2: PC (PITA) NEG : 6.224
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2
Pockels Cell Voltage NEG : 1.84371
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.146471
Photodiode on table : 412.263
Laser X position on QPD 1 : 182.922
Laser Y position on QPD 1 : 476.454
Laser X position on QPD 2 : -41.1762
Laser Y position on QPD 2 : -597.905
QPD 1 sum : -1.72618
QPD 2 sum : -1.1573
Position set point for adjustable
mirror 1 (either x or y) : -875[c]
Position set point for adjustable
mirror 2 (either x or y) : -3990[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point :
+47.1468
Polarisation in cavity : RIGHT
Reflection photodiode : 0.869804
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 5.18037
Calculated polarisation in cavity : 26.8312
Photodiode 1 after Wollaston prism : 0.00813922
Photodiode 2 after Wollaston prism : 0.00438565
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1589.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.08
Left Arm Q1 momentum : 3.14101
Left Arm Q1 gauss meter : -0.19941
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.76
Left Arm Q2 momentum : 3.14156
Left Arm Q2 gauss meter : 0.7106
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1102.97
Left Arm D1 momentum : 3.14163
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.55
Left Arm Q3 momentum : 3.14116
Left Arm Q3 gauss meter : -0.63089
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2361.96
Right Arm Q1 momentum : 3.14118
Right Arm Q1 gauss meter : -0.05864
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.87
Right Arm Q2 momentum : 3.1412
Right Arm Q2 gauss meter : 0.7061
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.85
Right Arm D1 momentum : 3.14166
Right Arm D1 NMR : 1.16583
Right Arm Q3 power supply current : 1249.98
Right Arm Q3 momentum : 3.14138
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.75781
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0170898
Left Arm Bottom VDC voltage : 0.0175781
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00878906
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0310165
Current on Unser monitor : -6.3259
Current on Upstream bcm : 0.0379918
Current on Downstream bcm : 0.0240413
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 12.0342
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.21
Delta(E)/E width (MV_AI_DXWID) : 3.96909
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : IPM1C12.XPOS --- Invalid channel name
IPM1C12.YPOS : IPM1C12.YPOS --- Invalid channel name
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : IPM1C12.XPOS --- Invalid channel name
Survey Y offset bpm12 : IPM1C12.YPOS --- Invalid channel name
Survey X HI SAT bpm12 : IPM1C12Alrm.B2 --- Invalid channel name
Survey Y HI SAT bpm12 : IPM1C12Alrm.B3 --- Invalid channel name
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619629
HacL_HPE1313A:0_Ch58 : -0.203613
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : 0.0185547
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.0287598
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.965332
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.9
pressure fill target H2 : 28.6244
pressure fill bottle H2 : 29.1325
pressure ballast H2 : 27.9957
pressure exhaust H2 : 28.1727
cryogen input temp : 13.7
crogen return flow : 24.3673
JT valve setting : 52.832
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12569 -d '2009-09-22 09:31:13' -t 17740748 -s OUT