    User name apar

    Log entry time 16:55:01 on September 25, 2009

    Entry number 291616

    keyword=Start_Parity_Run_12678__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production, 100 uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 12678 at Fri Sep 25 16:54:54 EDT 2009
    CODA Configuration: happex3
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 19715
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 169
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.549
    Gun2: PC (PITA) NEG                      : 6.161
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.99267
    Pockels Cell Voltage NEG                 : 1.84127
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 992.572
    Photodiode on table                      : 423.23
    Laser X position on QPD 1                : 149.474
    Laser Y position on QPD 1                : 484.305
    Laser X position on QPD 2                : -21.7046
    Laser Y position on QPD 2                : -588.454
    QPD 1 sum                                : -1.93127
    QPD 2 sum                                : -1.30745
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -175[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -2470[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1404
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.348532
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.199597
    Fast locking signal sent to laser        : 1.2397
    Calculated polarisation in cavity        : 82.7082
    Photodiode 1 after Wollaston prism       : 71.6653
    Photodiode 2 after Wollaston prism       : 6.78251
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1589.4
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.19
    Left Arm Q1 momentum                     : 3.14115
    Left Arm Q1 gauss meter                  : -0.19937
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.79
    Left Arm Q2 momentum                     : 3.14163
    Left Arm Q2 gauss meter                  : 0.7106
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1103.83
    Left Arm D1 momentum                     : 3.14166
    Left Arm D1 NMR                          : 1.1634
    Left Arm Q3 power supply current         : 1250.87
    Left Arm Q3 momentum                     : 3.14195
    Left Arm Q3 gauss meter                  : -0.6311
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.17
    Right Arm Q1 momentum                    : 3.14146
    Right Arm Q1 gauss meter                 : -0.05864
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.91
    Right Arm Q2 momentum                    : 3.14129
    Right Arm Q2 gauss meter                 : 0.7062
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.85
    Right Arm D1 momentum                    : 3.14154
    Right Arm D1 NMR                         : 1.16579
    Right Arm Q3 power supply current        : 1250.02
    Right Arm Q3 momentum                    : 3.14147
    Right Arm Q3 gauss meter                 : 0.5593
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.36719
    Left Arm Bottom VDC Current              : 1.41602
    Right Arm Top VDC Current                : -1.66016
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 0.0170898
    Left Arm Bottom VDC voltage              : 0.0175781
    Right Arm Top VDC voltage                : -0.0112305
    Right Arm Bottom VDC voltage             : -0.00927734
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 83.3725
    Current on Unser monitor                 : 74.8033
    Current on Upstream bcm                  : 80.9114
    Current on Downstream bcm                : 85.8336
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 98.2015
    Tiefenbach Hall A energy                 : 3483.01
    Tiefenbach Hall C energy                 : 2344.1
    Delta(E)/E width (MV_AI_DXWID)           : 4.11681
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0.522551
    IPM1C12.YPOS                             : 0.149215
    IPM1H04A.XPOS                            : -0.389075
    IPM1H04A.YPOS                            : 1.74041
    IPM1H04B.XPOS                            : -1.30114
    IPM1H04B.YPOS                            : 2.08254
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.522551
    Survey Y offset bpm12                     : 0.137411
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.619727
    HacL_HPE1313A:0_Ch58                     : -0.206543
    HacL_HPE1313A:0_Ch55                     : 22.9004
    HacL_HPE1313A:0_Ch54                     : 0.0161133
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0185547
    HacR_HPE1313A:0_Ch58                     : -0.627441
    HacR_HPE1313A:0_Ch55                     : 22.168
    HacR_HPE1313A:0_Ch54                     : -0.964355
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 72.5
    Encoder position                         : 17740744
    temperature loop 3-1                      : 18.96
    temperature loop 3-2                      : 18.96
    temperature loop 3-3                      : 0.91
    pressure fill target H2                   : 27.7852
    pressure fill bottle H2                   : 28.014
    pressure ballast H2                       : 27.7073
    pressure exhaust H2                       : 27.7165
    cryogen input temp                        : 13.8
    crogen return flow                        : 24.2506
     JT valve setting                         : 52.4902
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12678 -d '2009-09-25 16:54:50' -t 17740744 -s OUT