• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 02:47:07 on September 26, 2009

    Entry number 291680

    keyword=Start_Parity_Run_12690__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production, 100 uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 12690 at Sat Sep 26 02:46:37 EDT 2009
    CODA Configuration: happex3
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 19722
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 62
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.532
    Gun2: PC (PITA) NEG                      : 6.178
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2
    Pockels Cell Voltage NEG                 : 1.84371
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr752mW
    Calculated power in cavity               : 792.453
    Photodiode on table                      : 424.227
    Laser X position on QPD 1                : 137.881
    Laser Y position on QPD 1                : 490.196
    Laser X position on QPD 2                : -18.1906
    Laser Y position on QPD 2                : -584.397
    QPD 1 sum                                : -1.91296
    QPD 2 sum                                : -1.32454
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -175[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -2470[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1184
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.798999
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : 8.25673
    Calculated polarisation in cavity        : 99.9842
    Photodiode 1 after Wollaston prism       : 0.0118072
    Photodiode 2 after Wollaston prism       : 0.00493386
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1589.4
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -4
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -6.1
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.19
    Left Arm Q1 momentum                     : 3.14115
    Left Arm Q1 gauss meter                  : -0.19938
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.8
    Left Arm Q2 momentum                     : 3.14166
    Left Arm Q2 gauss meter                  : 0.7107
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1103.83
    Left Arm D1 momentum                     : 3.14165
    Left Arm D1 NMR                          : 1.1634
    Left Arm Q3 power supply current         : 1250.89
    Left Arm Q3 momentum                     : 3.14201
    Left Arm Q3 gauss meter                  : -0.63113
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.17
    Right Arm Q1 momentum                    : 3.14146
    Right Arm Q1 gauss meter                 : -0.05865
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.91
    Right Arm Q2 momentum                    : 3.1413
    Right Arm Q2 gauss meter                 : 0.7062
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.85
    Right Arm D1 momentum                    : 3.14154
    Right Arm D1 NMR                         : 1.16579
    Right Arm Q3 power supply current        : 1250.04
    Right Arm Q3 momentum                    : 3.14151
    Right Arm Q3 gauss meter                 : 0.5593
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.36719
    Left Arm Bottom VDC Current              : 1.46484
    Right Arm Top VDC Current                : -1.66016
    Right Arm Bottom VDC Current             : -1.36719
    Left Arm Top VDC voltage                 : 0.0175781
    Left Arm Bottom VDC voltage              : 0.0180664
    Right Arm Top VDC voltage                : -0.0107422
    Right Arm Bottom VDC voltage             : -0.00878906
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0311658
    Current on Unser monitor                 : -6.6481
    Current on Upstream bcm                  : 0.0383485
    Current on Downstream bcm                : 0.023983
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.0100632
    Tiefenbach Hall A energy                 :  halla_MeV --- Invalid channel name
    Tiefenbach Hall C energy                 :  hallc_MeV --- Invalid channel name
    Delta(E)/E width (MV_AI_DXWID)           : 4.40682
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                :  Arc1_dpp --- Invalid channel name
    Arc2 dp/p                                :  Arc2_dpp --- Invalid channel name
    Left Arm Collimator                      : 0.619775
    HacL_HPE1313A:0_Ch58                     : -0.206055
    HacL_HPE1313A:0_Ch55                     : 22.9492
    HacL_HPE1313A:0_Ch54                     : 0.0170898
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0163086
    HacR_HPE1313A:0_Ch58                     : -0.626953
    HacR_HPE1313A:0_Ch55                     : 22.3633
    HacR_HPE1313A:0_Ch54                     : -0.964844
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 71.5
    Encoder position                         : 17740744
    temperature loop 3-1                      : 18.88
    temperature loop 3-2                      : 18.88
    temperature loop 3-3                      : 0.9
    pressure fill target H2                   : 27.5227
    pressure fill bottle H2                   : 27.8111
    pressure ballast H2                       : 27.6036
    pressure exhaust H2                       : 27.5837
    cryogen input temp                        : 13.9
    crogen return flow                        : 24.3818
     JT valve setting                         : 53.0762
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12690 -d '2009-09-26 02:46:21' -t 17740744 -s OUT