NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 19:41:55 on September 27, 2009
Entry number 291965
keyword=Start_Parity_Run_12741__CODA_Config=happex3_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production, 100 uA,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=72Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 12741 at Sun Sep 27 19:41:50 EDT 2009
CODA Configuration: happex3
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19791
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 235
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5.8
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.568
Gun2: PC (PITA) NEG : 6.132
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.83639
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.148512
Photodiode on table : 395.065
Laser X position on QPD 1 : 144.012
Laser Y position on QPD 1 : 485.317
Laser X position on QPD 2 : -22.0458
Laser Y position on QPD 2 : -580.996
QPD 1 sum : -2.00452
QPD 2 sum : -1.38436
Position set point for adjustable
mirror 1 (either x or y) : -175[c]
Position set point for adjustable
mirror 2 (either x or y) : -2470[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1107
Polarisation in cavity : RIGHT
Reflection photodiode : 0.871025
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 0.913752
Calculated polarisation in cavity : 12.6821
Photodiode 1 after Wollaston prism : 0.00661312
Photodiode 2 after Wollaston prism : 0.004624
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -6.1
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.88
Left Arm Q1 momentum : 3.14207
Left Arm Q1 gauss meter : -0.19939
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.77
Left Arm Q2 momentum : 3.1416
Left Arm Q2 gauss meter : 0.7106
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.83
Left Arm D1 momentum : 3.14165
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.86
Left Arm Q3 momentum : 3.14194
Left Arm Q3 gauss meter : -0.63113
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.23
Right Arm Q1 momentum : 3.14153
Right Arm Q1 gauss meter : -0.05862
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.9
Right Arm Q2 momentum : 3.14127
Right Arm Q2 gauss meter : 0.7061
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.85
Right Arm D1 momentum : 3.1416
Right Arm D1 NMR : 1.16581
Right Arm Q3 power supply current : 1250.01
Right Arm Q3 momentum : 3.14144
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0170898
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00878906
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 97.363
Current on Unser monitor : 88.985
Current on Upstream bcm : 95.3349
Current on Downstream bcm : 99.3911
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 100.848
Tiefenbach Hall A energy : 3482.97
Tiefenbach Hall C energy : 2344.13
Delta(E)/E width (MV_AI_DXWID) : 2.92873
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.533368
IPM1C12.YPOS : 0.124555
IPM1H04A.XPOS : -0.281321
IPM1H04A.YPOS : 1.84948
IPM1H04B.XPOS : -1.3133
IPM1H04B.YPOS : 2.11014
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.533368
Survey Y offset bpm12 : 0.124555
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619775
HacL_HPE1313A:0_Ch58 : -0.20752
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.0161133
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0120605
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.96582
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72.5
Encoder position : 17740742
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.91
pressure fill target H2 : 27.9393
pressure fill bottle H2 : 27.9774
pressure ballast H2 : 27.5532
pressure exhaust H2 : 27.2862
cryogen input temp : 13.7
crogen return flow : 24.4477
JT valve setting : 53.0762
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 12741 -d '2009-09-27 19:41:41' -t 17740742 -s OUT