Log entry time 07:20:15 on October 1, 2009
Entry number 292532
keyword=End_of_Parity_Run_12854__CODA_Config=HapNoQweak
************************************************
Run Number: 12854
End of Run Comment:
Run_type=Cosmics,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=pedestal runs,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 12854 at Thu Oct 1 07:20:06 EDT 2009
CODA Configuration: HapNoQweak
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 19926
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.4
Wien field : 11.363
Laser attenuation Hall A : 55
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5.2
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.2
Gun2: PC (PITA) NEG : 6.5
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01221
Pockels Cell Voltage NEG : 1.82173
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr757mW
Calculated power in cavity : 0.263256
Photodiode on table : 407.029
Laser X position on QPD 1 : 136.626
Laser Y position on QPD 1 : 502.3
Laser X position on QPD 2 : -26.0764
Laser Y position on QPD 2 : -596.439
QPD 1 sum : -1.77989
QPD 2 sum : -1.25374
Position set point for adjustable
mirror 1 (either x or y) : -375[c]
Position set point for adjustable
mirror 2 (either x or y) : 1580[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2563
Polarisation in cavity : RIGHT
Reflection photodiode : 0.871025
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -6.75884
Calculated polarisation in cavity : 51.7118
Photodiode 1 after Wollaston prism : 0.00655957
Photodiode 2 after Wollaston prism : 0.00469551
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2364.1
Left Arm Q1 momentum : 3.14236
Left Arm Q1 gauss meter : -0.19942
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.78
Left Arm Q2 momentum : 3.14163
Left Arm Q2 gauss meter : 0.7099
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.83
Left Arm D1 momentum : 3.14158
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.87
Left Arm Q3 momentum : 3.14195
Left Arm Q3 gauss meter : -0.63115
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.000196182
Right Arm Q1 gauss meter : -2.37e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0117244
Right Arm Q2 momentum : -2.72429e-05
Right Arm Q2 gauss meter : 0.0004601
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.01832
Right Arm D1 momentum : 0.00227237
Right Arm D1 NMR : 1.14435
Right Arm Q3 power supply current : 0.0953318
Right Arm Q3 momentum : 0.000842382
Right Arm Q3 gauss meter : -0.0001459
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.75781
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0329661
Current on Unser monitor : -7.14129
Current on Upstream bcm : 0.0416954
Current on Downstream bcm : 0.0242215
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 30.2077
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2365.05
Delta(E)/E width (MV_AI_DXWID) : 3.32408
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2370.75
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619678
HacL_HPE1313A:0_Ch58 : -0.206055
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0170898
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0150879
HacR_HPE1313A:0_Ch58 : -0.631348
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.964355
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 73
Encoder position : 3202555
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.9
pressure fill target H2 : 27.1
pressure fill bottle H2 : 27.3106
pressure ballast H2 : 26.5843
pressure exhaust H2 : 26.9642
cryogen input temp : 14.2
crogen return flow : 23.4662
JT valve setting : 52.6367
-----------------------------------------