    User name silwal

    Log entry time 22:21:06 on October 02, 2009

    Entry number 292810

    keyword=helicity errors: software issue, most of the data/pair sync fine

    previously helicity errors were seen for runs: 12833-36, 12844, 12850-72,
    12887. these were all taken in "HapNoQweak" configuration. all the runs
    taken in "Happex" configuration are fine. the helicity errors were due to
    incorrect .db files. there were two copies of helicity from the injector
    crate in the .db file. the HapNoQweak.def file looked fine, but I had
    modified it in vi. and although the .def file only had CountHouse,
    RightSpec and LeftSpec, when the script that created .db file read
    LeftSpec, it went back to reading CountHouse instead of exiting the .def
    file. the cause of this could have been some blank spaces that i
    neglected to delete in the .def while using vi.

    all the .db files have been corrected, and usable data recovered.
    run # 12872-75 was not taken with pair sync, so is unusable.

    pair sync: the incorrect .db files also had extra copies of the injector
    scaler variables. so the pair sync errors seen for "HapNoQweak" config
    was probably due to incorrect datamap. after correcting the .db file, i
    did not see any pair sync errors. i looked at about 10 runs.

    total beam time loss: 1 hr, 20 minutes
    (runs taken between 00:02 and 1:20 Friday,12872-72 are unusable)