NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 01:35:09 on October 3, 2009
Entry number 292835
keyword=End_of_Parity_Run_12900__CODA_Config=Happex
************************************************
Run Number: 12900
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 12900 at Sat Oct 3 01:34:59 EDT 2009
CODA Configuration: Happex
Compton Run Number : 19992
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.4
Wien field : 11.363
Laser attenuation Hall A : 146
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 6.2
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.354
Gun2: PC (PITA) NEG : 6.346
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 0.146471
Photodiode on table : 500.499
Laser X position on QPD 1 : 233.049
Laser Y position on QPD 1 : 288.519
Laser X position on QPD 2 : -23.1777
Laser Y position on QPD 2 : -380.978
QPD 1 sum : -0.31374
QPD 2 sum : -0.300311
Position set point for adjustable
mirror 1 (either x or y) : -70[c]
Position set point for adjustable
mirror 2 (either x or y) : 2220[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.0708
Polarisation in cavity : RIGHT
Reflection photodiode : 0.105597
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 1.05658
Calculated polarisation in cavity : 18.8777
Photodiode 1 after Wollaston prism : 0.00746988
Photodiode 2 after Wollaston prism : 0.00457633
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2364.1
Left Arm Q1 momentum : 3.14236
Left Arm Q1 gauss meter : -0.19939
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.81
Left Arm Q2 momentum : 3.14169
Left Arm Q2 gauss meter : 0.7099
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.83
Left Arm D1 momentum : 3.14166
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.89
Left Arm Q3 momentum : 3.14201
Left Arm Q3 gauss meter : -0.6312
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2361.96
Right Arm Q1 momentum : 3.14118
Right Arm Q1 gauss meter : -0.05863
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.03
Right Arm Q2 momentum : 3.14156
Right Arm Q2 gauss meter : 0.7061
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.83
Right Arm D1 momentum : 3.1416
Right Arm D1 NMR : 1.16581
Right Arm Q3 power supply current : 1249.99
Right Arm Q3 momentum : 3.1414
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.75781
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : -0.0102539
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 97.3018
Current on Unser monitor : 89.9423
Current on Upstream bcm : 94.8564
Current on Downstream bcm : 99.7471
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 105.747
Tiefenbach Hall A energy : 3483.04
Tiefenbach Hall C energy : 2344.08
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.521122
IPM1C12.YPOS : 0.101525
IPM1H04A.XPOS : -0.270949
IPM1H04A.YPOS : 1.67383
IPM1H04B.XPOS : -1.30154
IPM1H04B.YPOS : 2.10524
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.521122
Survey Y offset bpm12 : 0.101525
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619727
HacL_HPE1313A:0_Ch58 : -0.20752
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.015625
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0141602
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.963379
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740744
temperature loop 3-1 : 18.99
temperature loop 3-2 : 19
temperature loop 3-3 : 0.91
pressure fill target H2 : 27.8431
pressure fill bottle H2 : 27.9911
pressure ballast H2 : 27.6967
pressure exhaust H2 : 27.1946
cryogen input temp : 14.1
crogen return flow : 25.3991
JT valve setting : 55.0293
-----------------------------------------