Log entry time 21:22:37 on October 9, 2009
Entry number 294070
keyword=Start_Parity_Run_13110__CODA_Config=Happex_Run_type=Calibration,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=rates studies,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 13110 at Fri Oct 9 21:22:31 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20268
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 77
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.52
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.824
Gun2: PC (PITA) NEG : 5.876
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.8315
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.155362
Photodiode on table : 407.777
Laser X position on QPD 1 : 140.867
Laser Y position on QPD 1 : 495.657
Laser X position on QPD 2 : -20.4289
Laser Y position on QPD 2 : -597.954
QPD 1 sum : -1.82628
QPD 2 sum : -1.28426
Position set point for adjustable
mirror 1 (either x or y) : -470[c]
Position set point for adjustable
mirror 2 (either x or y) : 1500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.0827
Polarisation in cavity : RIGHT
Reflection photodiode : 0.841726
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 6.88702
Calculated polarisation in cavity : 17.3082
Photodiode 1 after Wollaston prism : 0.00720214
Photodiode 2 after Wollaston prism : 0.00507687
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -2099.5
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1700.3
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1698.6
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.19
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19936
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.59
Left Arm Q2 momentum : 3.14118
Left Arm Q2 gauss meter : 0.7099
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.51
Left Arm D1 momentum : 3.1416
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.62
Left Arm Q3 momentum : 3.14133
Left Arm Q3 gauss meter : -0.63072
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.39
Right Arm Q1 momentum : 3.14174
Right Arm Q1 gauss meter : -0.05863
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.71
Right Arm Q2 momentum : 3.14084
Right Arm Q2 gauss meter : 0.7059
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.8
Right Arm D1 momentum : 3.14162
Right Arm D1 NMR : 1.16582
Right Arm Q3 power supply current : 1249.9
Right Arm Q3 momentum : 3.14116
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -2.58789
Left Arm Bottom VDC Current : -1.31836
Right Arm Top VDC Current : -23.6328
Right Arm Bottom VDC Current : -3.4668
Left Arm Top VDC voltage : 3.99805
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4.00342
Right Arm Bottom VDC voltage : 3.99512
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 5.0791
Current on Unser monitor : -0.876664
Current on Upstream bcm : 4.94855
Current on Downstream bcm : 5.20965
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 39.5201
Tiefenbach Hall A energy : 3482.86
Tiefenbach Hall C energy : 2344.1
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.708992
IPM1C12.YPOS : 0.080963
IPM1H04A.XPOS : -0.305041
IPM1H04A.YPOS : 1.8534
IPM1H04B.XPOS : -1.30617
IPM1H04B.YPOS : 2.09741
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.708992
Survey Y offset bpm12 : 0.080963
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619873
HacL_HPE1313A:0_Ch58 : -0.211914
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.012207
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0119629
HacR_HPE1313A:0_Ch58 : -0.626465
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.962891
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.9
pressure fill target H2 : 27.9942
pressure fill bottle H2 : 28.3116
pressure ballast H2 : 27.5319
pressure exhaust H2 : 27.3716
cryogen input temp : 13.8
crogen return flow : 25.4574
JT valve setting : 53.418
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13110 -d '2009-10-09 21:22:18' -t 17740748 -s IN