NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 22:08:04 on October 9, 2009
Entry number 294092
keyword=End_of_Parity_Run_13114__CODA_Config=Happex
************************************************
Run Number: 13114
End of Run Comment:
Run_type=Calibration,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=rates studies, 10 uA, det1/2 on parity DAQ,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 13114 at Fri Oct 9 22:07:56 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20271
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 88
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.61
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.824
Gun2: PC (PITA) NEG : 5.876
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 911.241
Photodiode on table : 398.305
Laser X position on QPD 1 : 151.558
Laser Y position on QPD 1 : 490.964
Laser X position on QPD 2 : -22.7898
Laser Y position on QPD 2 : -597.627
QPD 1 sum : -1.81896
QPD 2 sum : -1.24519
Position set point for adjustable
mirror 1 (either x or y) : -470[c]
Position set point for adjustable
mirror 2 (either x or y) : 1500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.0946
Polarisation in cavity : LEFT
Reflection photodiode : 0.354636
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.111701
Fast locking signal sent to laser : 6.70024
Calculated polarisation in cavity : 98.1705
Photodiode 1 after Wollaston prism : 0.660321
Photodiode 2 after Wollaston prism : 71.5266
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1699.6
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1698.6
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.19
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19936
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.58
Left Arm Q2 momentum : 3.14116
Left Arm Q2 gauss meter : 0.71
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.52
Left Arm D1 momentum : 3.14161
Left Arm D1 NMR : 1.16339
Left Arm Q3 power supply current : 1250.62
Left Arm Q3 momentum : 3.14133
Left Arm Q3 gauss meter : -0.6307
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.44
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05862
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.7
Right Arm Q2 momentum : 3.14081
Right Arm Q2 gauss meter : 0.706
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.8
Right Arm D1 momentum : 3.14164
Right Arm D1 NMR : 1.16582
Right Arm Q3 power supply current : 1249.9
Right Arm Q3 momentum : 3.14117
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -2.63672
Left Arm Bottom VDC Current : -0.292969
Right Arm Top VDC Current : -29.7852
Right Arm Bottom VDC Current : -3.75977
Left Arm Top VDC voltage : 4.00098
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4.00732
Right Arm Bottom VDC voltage : 4.00049
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 10.2598
Current on Unser monitor : 4.37015
Current on Upstream bcm : 10.0031
Current on Downstream bcm : 10.5165
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 45.1043
Tiefenbach Hall A energy : 3482.88
Tiefenbach Hall C energy : 2344.1
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.685021
IPM1C12.YPOS : 0.130194
IPM1H04A.XPOS : -0.315208
IPM1H04A.YPOS : 1.83415
IPM1H04B.XPOS : -1.29473
IPM1H04B.YPOS : 2.08716
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.685021
Survey Y offset bpm12 : 0.130194
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619873
HacL_HPE1313A:0_Ch58 : -0.212402
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.0126953
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0318359
HacR_HPE1313A:0_Ch58 : -0.627441
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.962891
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -3.8917
Arc OTR y-position : -1.307
Arc OTR x-width : 1.75356
Arc OTR y-width : 1.7231
Arc OTR data valid flag : No
Arc OTR In/Out : MaxPix is Bad
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.9
pressure fill target H2 : 28.0598
pressure fill bottle H2 : 28.249
pressure ballast H2 : 27.7012
pressure exhaust H2 : 27.6951
cryogen input temp : 13.8
crogen return flow : 25.0223
JT valve setting : 53.3203
-----------------------------------------