    User name apar

    Log entry time 23:32:19 on October 9, 2009

    Entry number 294125

    keyword=End_of_Parity_Run_13124__CODA_Config=Happex
    ************************************************
     Run Number: 13124
     End of Run Comment:
    
    Run_type=Calibration,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=rates studies, 20 uA, det1/2 on spectrometer DAQ,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=20cm Al Dummy
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13124 at Fri Oct  9 23:32:10 EDT 2009
    CODA Configuration: Happex
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20275
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 101
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.58
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.824
    Gun2: PC (PITA) NEG                      : 5.876
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00977
    Pockels Cell Voltage NEG                 : 1.83394
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 983.486
    Photodiode on table                      : 408.275
    Laser X position on QPD 1                : 146.205
    Laser Y position on QPD 1                : 493.58
    Laser X position on QPD 2                : -22.2446
    Laser Y position on QPD 2                : -601.685
    QPD 1 sum                                : -1.82628
    QPD 2 sum                                : -1.27571
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -470[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 1500[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2091
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.343649
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : -0.239883
    Fast locking signal sent to laser        : -3.51401
    Calculated polarisation in cavity        : 97.8576
    Photodiode 1 after Wollaston prism       : 76.7684
    Photodiode 2 after Wollaston prism       : 0.831248
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -2099.5
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1699.6
    S0 Back End, HV - Left Slot7 Card2 Ch9    : -1698.6
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : 14.0003
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.19
    Left Arm Q1 momentum                     : 3.14115
    Left Arm Q1 gauss meter                  : -0.19934
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.58
    Left Arm Q2 momentum                     : 3.14115
    Left Arm Q2 gauss meter                  : 0.7099
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1103.51
    Left Arm D1 momentum                     : 3.14161
    Left Arm D1 NMR                          : 1.16339
    Left Arm Q3 power supply current         : 1250.62
    Left Arm Q3 momentum                     : 3.14133
    Left Arm Q3 gauss meter                  : -0.63073
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.44
    Right Arm Q1 momentum                    : 3.14181
    Right Arm Q1 gauss meter                 : -0.05865
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.69
    Right Arm Q2 momentum                    : 3.14079
    Right Arm Q2 gauss meter                 : 0.706
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.8
    Right Arm D1 momentum                    : 3.14162
    Right Arm D1 NMR                         : 1.16582
    Right Arm Q3 power supply current        : 1249.9
    Right Arm Q3 momentum                    : 3.14116
    Right Arm Q3 gauss meter                 : 0.5593
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : -2.97852
    Left Arm Bottom VDC Current              : 2.68555
    Right Arm Top VDC Current                : -32.1777
    Right Arm Bottom VDC Current             : -0.878906
    Left Arm Top VDC voltage                 : 4.00244
    Left Arm Bottom VDC voltage              : 4.00195
    Right Arm Top VDC voltage                : 4.00391
    Right Arm Bottom VDC voltage             : 4.00537
    -----------------------------------------
     Beam Info
    -----------------------------------------
    Average current of the two cavities      : 20.3042
    Current on Unser monitor                 : 14.6162
    Current on Upstream bcm                  : 19.761
    Current on Downstream bcm                : 20.8474
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 55.0324
    Tiefenbach Hall A energy                 : 3482.87
    Tiefenbach Hall C energy                 : 2344.12
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0.68763
    IPM1C12.YPOS                             : 0.102835
    IPM1H04A.XPOS                            : -0.32122
    IPM1H04A.YPOS                            : 1.8436
    IPM1H04B.XPOS                            : -1.29848
    IPM1H04B.YPOS                            : 2.10025
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Survey X offset bpm12                     : 0.68763
    Survey Y offset bpm12                     : 0.102835
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.619873
    HacL_HPE1313A:0_Ch58                     : -0.212402
    HacL_HPE1313A:0_Ch55                     : 23.1445
    HacL_HPE1313A:0_Ch54                     : 0.0131836
    Left Arm Angle Floor Angle               : 14
    Left Arm Angle Vernier                   : 31.1
    Left Arm Scattering Angle                : 14.0003
    Right Arm Collimator                     : 0.0185059
    HacR_HPE1313A:0_Ch58                     : -0.627441
    HacR_HPE1313A:0_Ch55                     : 22.4121
    HacR_HPE1313A:0_Ch54                     : -0.962891
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -3.7304
    Arc OTR  y-position                      : -1.27344
    Arc OTR  x-width                         : 1.89887
    Arc OTR  y-width                         : 1.70993
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : MaxPix is Bad
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 64.5
    Encoder position                         : 11801563
    temperature loop 3-1                      : 19
    temperature loop 3-2                      : 19.01
    temperature loop 3-3                      : 0.9
    pressure fill target H2                   : 27.9606
    pressure fill bottle H2                   : 28.3177
    pressure ballast H2                       : 27.7043
    pressure exhaust H2                       : 27.2099
    cryogen input temp                        : 13.8
    crogen return flow                        : 25.3827
     JT valve setting                         : 53.1738
    -----------------------------------------