NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 05:46:50 on October 10, 2009
Entry number 294185
keyword=Start_Parity_Run_13132__CODA_Config=Happex_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 13132 at Sat Oct 10 05:46:42 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20275
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 189
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.33
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.962
Gun2: PC (PITA) NEG : 5.738
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00977
Pockels Cell Voltage NEG : 1.83639
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 0.1461
Photodiode on table : 409.272
Laser X position on QPD 1 : 150.703
Laser Y position on QPD 1 : 490.518
Laser X position on QPD 2 : -23.5183
Laser Y position on QPD 2 : -596.22
QPD 1 sum : -1.85802
QPD 2 sum : -1.29769
Position set point for adjustable
mirror 1 (either x or y) : -470[c]
Position set point for adjustable
mirror 2 (either x or y) : 1500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.0685
Polarisation in cavity : RIGHT
Reflection photodiode : 0.851492
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -7.35213
Calculated polarisation in cavity : 76.0201
Photodiode 1 after Wollaston prism : 0.0353414
Photodiode 2 after Wollaston prism : 0.00481468
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -6.9
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.19
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19935
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.59
Left Arm Q2 momentum : 3.14119
Left Arm Q2 gauss meter : 0.7099
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.52
Left Arm D1 momentum : 3.14161
Left Arm D1 NMR : 1.16339
Left Arm Q3 power supply current : 1250.62
Left Arm Q3 momentum : 3.14134
Left Arm Q3 gauss meter : -0.63072
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.44
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05863
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.71
Right Arm Q2 momentum : 3.14083
Right Arm Q2 gauss meter : 0.706
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.8
Right Arm D1 momentum : 3.14158
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1249.9
Right Arm Q3 momentum : 3.14118
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.85547
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : 0.000976562
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 98.1949
Current on Unser monitor : 92.6278
Current on Upstream bcm : 95.0448
Current on Downstream bcm : 101.345
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 131.892
Tiefenbach Hall A energy : 3483.12
Tiefenbach Hall C energy : 2344.12
Delta(E)/E width (MV_AI_DXWID) : 0.266289
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.36634
IPM1C12.YPOS : 0.0877089
IPM1H04A.XPOS : -0.308422
IPM1H04A.YPOS : 1.85387
IPM1H04B.XPOS : -1.27416
IPM1H04B.YPOS : 2.09759
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.36634
Survey Y offset bpm12 : 0.0877089
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619873
HacL_HPE1313A:0_Ch58 : -0.211426
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.0146484
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0119141
HacR_HPE1313A:0_Ch58 : -0.628418
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.965332
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 73
Encoder position : 17740748
temperature loop 3-1 : 18.98
temperature loop 3-2 : 18.99
temperature loop 3-3 : 0.91
pressure fill target H2 : 27.8477
pressure fill bottle H2 : 28.1544
pressure ballast H2 : 27.602
pressure exhaust H2 : 27.5547
cryogen input temp : 13.9
crogen return flow : 25.2401
JT valve setting : 53.5645
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13132 -d '2009-10-10 05:46:37' -t 17740748 -s IN