User name apar
Log entry time 09:54:15 on October 10, 2009
Entry number 294211
keyword=Start_Parity_Run_13137__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=non-production compton test,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 13137 at Sat Oct 10 09:54:09 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20276
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 188
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5.12
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.299
Gun2: PC (PITA) NEG : 6.401
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.82662
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 949.871
Photodiode on table : 408.774
Laser X position on QPD 1 : 154.302
Laser Y position on QPD 1 : 486.87
Laser X position on QPD 2 : -24.5981
Laser Y position on QPD 2 : -598.795
QPD 1 sum : -1.8568
QPD 2 sum : -1.28426
Position set point for adjustable
mirror 1 (either x or y) : -470[c]
Position set point for adjustable
mirror 2 (either x or y) : 1500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1591
Polarisation in cavity : RIGHT
Reflection photodiode : 0.390038
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.247207
Fast locking signal sent to laser : -5.1291
Calculated polarisation in cavity : 97.8619
Photodiode 1 after Wollaston prism : 74.2704
Photodiode 2 after Wollaston prism : 0.802574
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1590.2
S0 Front End, HV - Left Slot7 Card2 Ch9 : -3.3
S0 Back End, HV - Left Slot7 Card2 Ch9 : -6.1
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.24
Left Arm Q1 momentum : 3.14122
Left Arm Q1 gauss meter : -0.19932
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.59
Left Arm Q2 momentum : 3.14118
Left Arm Q2 gauss meter : 0.7099
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.52
Left Arm D1 momentum : 3.14161
Left Arm D1 NMR : 1.16339
Left Arm Q3 power supply current : 1250.62
Left Arm Q3 momentum : 3.14133
Left Arm Q3 gauss meter : -0.63072
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.49
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05863
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.71
Right Arm Q2 momentum : 3.14084
Right Arm Q2 gauss meter : 0.706
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.8
Right Arm D1 momentum : 3.14158
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1249.9
Right Arm Q3 momentum : 3.14118
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.41602
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : 0.000976562
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 98.7235
Current on Unser monitor : 90.9492
Current on Upstream bcm : 95.9052
Current on Downstream bcm : 101.542
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 133.051
Tiefenbach Hall A energy : 3483.03
Tiefenbach Hall C energy : 2344.16
Delta(E)/E width (MV_AI_DXWID) : 0.281192
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.446453
IPM1C12.YPOS : 0.0882847
IPM1H04A.XPOS : -0.341573
IPM1H04A.YPOS : 1.88651
IPM1H04B.XPOS : -1.30269
IPM1H04B.YPOS : 2.11448
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.446453
Survey Y offset bpm12 : 0.0882847
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619824
HacL_HPE1313A:0_Ch58 : -0.213379
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0117188
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.011377
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.96582
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740748
temperature loop 3-1 : 18.99
temperature loop 3-2 : 19
temperature loop 3-3 : 0.91
pressure fill target H2 : 28.1346
pressure fill bottle H2 : 28.2643
pressure ballast H2 : 27.8798
pressure exhaust H2 : 27.6768
cryogen input temp : 13.8
crogen return flow : 25.4063
JT valve setting : 53.1738
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13137 -d '2009-10-10 09:53:19' -t 17740748 -s OUT