NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 21:28:14 on October 11, 2009
Entry number 294458
keyword=Start_Parity_Run_13181__CODA_Config=Happex_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production run,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 13181 at Sun Oct 11 21:28:08 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20331
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 189
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5.44
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.426
Gun2: PC (PITA) NEG : 6.274
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 912.239
Photodiode on table : 406.032
Laser X position on QPD 1 : 154.404
Laser Y position on QPD 1 : 487.722
Laser X position on QPD 2 : -24.1779
Laser Y position on QPD 2 : -599.528
QPD 1 sum : -1.85558
QPD 2 sum : -1.26228
Position set point for adjustable
mirror 1 (either x or y) : -470[c]
Position set point for adjustable
mirror 2 (either x or y) : 1500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.0836
Polarisation in cavity : RIGHT
Reflection photodiode : 0.410792
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.12635
Fast locking signal sent to laser : 5.68211
Calculated polarisation in cavity : 97.9808
Photodiode 1 after Wollaston prism : 71.3708
Photodiode 2 after Wollaston prism : 0.727923
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -6.1
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.19
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19933
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.62
Left Arm Q2 momentum : 3.14124
Left Arm Q2 gauss meter : 0.71
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.52
Left Arm D1 momentum : 3.14161
Left Arm D1 NMR : 1.16339
Left Arm Q3 power supply current : 1250.64
Left Arm Q3 momentum : 3.14139
Left Arm Q3 gauss meter : -0.63074
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.44
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05864
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.73
Right Arm Q2 momentum : 3.14087
Right Arm Q2 gauss meter : 0.706
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.84
Right Arm D1 momentum : 3.14158
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1249.92
Right Arm Q3 momentum : 3.14123
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.46484
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.019043
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : 0.000976562
Right Arm Bottom VDC voltage : -0.0102539
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 97.3059
Current on Unser monitor : 89.4828
Current on Upstream bcm : 94.9282
Current on Downstream bcm : 99.6835
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 97.7166
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.17
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.502977
IPM1C12.YPOS : 0.0949511
IPM1H04A.XPOS : -0.256267
IPM1H04A.YPOS : 1.84335
IPM1H04B.XPOS : -1.29515
IPM1H04B.YPOS : 2.09514
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.502977
Survey Y offset bpm12 : 0.0949511
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619873
HacL_HPE1313A:0_Ch58 : -0.211426
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.0107422
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0271973
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.962402
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72
Encoder position : 17740752
temperature loop 3-1 : 18.99
temperature loop 3-2 : 19
temperature loop 3-3 : 0.91
pressure fill target H2 : 26.627
pressure fill bottle H2 : 26.8803
pressure ballast H2 : 25.9327
pressure exhaust H2 : 26.3966
cryogen input temp : 14.2
crogen return flow : 25.1874
JT valve setting : 55.3223
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13181 -d '2009-10-11 21:27:55' -t 17740752 -s OUT