• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 02:34:22 on October 17, 2009

    Entry number 295287

    keyword=Start_Parity_Run_13333__CODA_Config=Happex_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=Production,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 13333 at Sat Oct 17 02:34:14 EDT 2009
    CODA Configuration: Happex
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20448
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 173
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.72
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.74
    Gun2: PC (PITA) NEG                      : 5.96
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00977
    Pockels Cell Voltage NEG                 : 1.83394
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 0.230566
    Photodiode on table                      : 476.57
    Laser X position on QPD 1                : 129.8
    Laser Y position on QPD 1                : 694.246
    Laser X position on QPD 2                : -12.6866
    Laser Y position on QPD 2                : -713.694
    QPD 1 sum                                : -1.81285
    QPD 2 sum                                : -1.19392
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -275[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 1790[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2104
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.770921
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.155649
    Fast locking signal sent to laser        : 1.27266
    Calculated polarisation in cavity        : 18.7989
    Photodiode 1 after Wollaston prism       : 0.00714859
    Photodiode 2 after Wollaston prism       : 0.00488619
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1589.4
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -4
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -5.3
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : 14.0003
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.13
    Left Arm Q1 momentum                     : 3.14101
    Left Arm Q1 gauss meter                  : -0.1993
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.6
    Left Arm Q2 momentum                     : 3.1412
    Left Arm Q2 gauss meter                  : 0.7098
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1103.51
    Left Arm D1 momentum                     : 3.1416
    Left Arm D1 NMR                          : 1.16338
    Left Arm Q3 power supply current         : 1250.63
    Left Arm Q3 momentum                     : 3.14136
    Left Arm Q3 gauss meter                  : -0.63075
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.92
    Right Arm Q1 momentum                    : 3.14245
    Right Arm Q1 gauss meter                 : -0.05862
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.69
    Right Arm Q2 momentum                    : 3.14079
    Right Arm Q2 gauss meter                 : 0.7059
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.79
    Right Arm D1 momentum                    : 3.14161
    Right Arm D1 NMR                         : 1.16581
    Right Arm Q3 power supply current        : 1249.9
    Right Arm Q3 momentum                    : 3.14118
    Right Arm Q3 gauss meter                 : 0.5593
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.41602
    Left Arm Bottom VDC Current              : 1.41602
    Right Arm Top VDC Current                : -1.75781
    Right Arm Bottom VDC Current             : -1.36719
    Left Arm Top VDC voltage                 : 0.019043
    Left Arm Bottom VDC voltage              : 0.0185547
    Right Arm Top VDC voltage                : 0.000488281
    Right Arm Bottom VDC voltage             : -0.0102539
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 96.7219
    Current on Unser monitor                 : 90.4009
    Current on Upstream bcm                  : 95.0936
    Current on Downstream bcm                : 98.3501
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 136.527
    Tiefenbach Hall A energy                 : 3483.21
    Tiefenbach Hall C energy                 : 2344.08
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0.487457
    IPM1C12.YPOS                             : 0.0699396
    IPM1H04A.XPOS                            : -0.368099
    IPM1H04A.YPOS                            : 1.71588
    IPM1H04B.XPOS                            : -1.3172
    IPM1H04B.YPOS                            : 2.08374
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.487457
    Survey Y offset bpm12                     : 0.0699396
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.620068
    HacL_HPE1313A:0_Ch58                     : -0.210938
    HacL_HPE1313A:0_Ch55                     : 23.1445
    HacL_HPE1313A:0_Ch54                     : 0.00830078
    Left Arm Angle Floor Angle               : 14
    Left Arm Angle Vernier                   : 31.1
    Left Arm Scattering Angle                : 14.0003
    Right Arm Collimator                     : 0.00932617
    HacR_HPE1313A:0_Ch58                     : -0.627441
    HacR_HPE1313A:0_Ch55                     : 22.6074
    HacR_HPE1313A:0_Ch54                     : -0.962402
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 72
    Encoder position                         : 17740748
    temperature loop 3-1                      : 18.99
    temperature loop 3-2                      : 19
    temperature loop 3-3                      : 0.91
    pressure fill target H2                   : 26.4607
    pressure fill bottle H2                   : 26.5812
    pressure ballast H2                       : 25.7374
    pressure exhaust H2                       : 25.7649
    cryogen input temp                        : 14
    crogen return flow                        : 25.1266
     JT valve setting                         : 56.543
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13333 -d '2009-10-17 02:33:58' -t 17740748 -s IN