NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 16:47:17 on October 17, 2009
Entry number 295368
keyword=End_of_Parity_Run_13350__CODA_Config=Happex
************************************************
Run Number: 13350
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 13350 at Sat Oct 17 16:47:07 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20467
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 183
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5.57
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.645
Gun2: PC (PITA) NEG : 6.055
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00977
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 855.138
Photodiode on table : 394.068
Laser X position on QPD 1 : 162.749
Laser Y position on QPD 1 : 480.683
Laser X position on QPD 2 : -25.8247
Laser Y position on QPD 2 : -592.673
QPD 1 sum : -1.90685
QPD 2 sum : -1.26473
Position set point for adjustable
mirror 1 (either x or y) : -275[c]
Position set point for adjustable
mirror 2 (either x or y) : 1790[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2333
Polarisation in cavity : LEFT
Reflection photodiode : 0.363181
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.137337
Fast locking signal sent to laser : -1.22139
Calculated polarisation in cavity : 98.1388
Photodiode 1 after Wollaston prism : 0.625944
Photodiode 2 after Wollaston prism : 66.6381
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down :
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.19
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19932
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.6
Left Arm Q2 momentum : 3.14121
Left Arm Q2 gauss meter : 0.7099
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.52
Left Arm D1 momentum : 3.1416
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.63
Left Arm Q3 momentum : 3.14135
Left Arm Q3 gauss meter : -0.63079
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.97
Right Arm Q1 momentum : 3.14252
Right Arm Q1 gauss meter : -0.05863
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.7
Right Arm Q2 momentum : 3.14082
Right Arm Q2 gauss meter : 0.706
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.79
Right Arm D1 momentum : 3.14157
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1249.9
Right Arm Q3 momentum : 3.14118
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.51367
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.85547
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : 0.000488281
Right Arm Bottom VDC voltage : -0.0107422
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 97.4686
Current on Unser monitor : 89.1965
Current on Upstream bcm : 95.0486
Current on Downstream bcm : 99.8885
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 137.11
Tiefenbach Hall A energy : 3482.86
Tiefenbach Hall C energy : 2344.09
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.65389
IPM1C12.YPOS : 0.0973865
IPM1H04A.XPOS : -0.374733
IPM1H04A.YPOS : 1.74064
IPM1H04B.XPOS : -1.30061
IPM1H04B.YPOS : 2.11266
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.65389
Survey Y offset bpm12 : 0.0973865
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.620068
HacL_HPE1313A:0_Ch58 : -0.212891
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.00878906
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0191406
HacR_HPE1313A:0_Ch58 : -0.62793
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.962891
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 73
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.92
pressure fill target H2 : 26.6941
pressure fill bottle H2 : 26.7994
pressure ballast H2 : 26.247
pressure exhaust H2 : 25.8762
cryogen input temp : 14
crogen return flow : 24.9669
JT valve setting : 56.8359
-----------------------------------------